• Artificial organs · May 2016

    Evaluation of Capiox RX25 and Quadrox-i Adult Hollow Fiber Membrane Oxygenators in a Simulated Cardiopulmonary Bypass Circuit.

    • Shigang Wang, Allen R Kunselman, and Akif Ündar.
    • Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA.
    • Artif Organs. 2016 May 1; 40 (5): E69-78.

    AbstractThe Capiox RX25 and Quadrox-i Adult oxygenators are commonly used in clinical adult cardiopulmonary bypass circuits. This study was designed to test the effectiveness of two adult oxygenators in order to evaluate gaseous microemboli (GME) trapping capability and hemodynamic performance. A simulated adult CPB circuit was used and primed with Ringer's lactate and packed red blood cells (hematocrit 25%). All trials were conducted at flow rates of 2-5 L/min (1 L/min increments) with a closed and open arterial filter purge line at 35°C. The postcannula pressure was maintained at 100 mm Hg. After a 5 cc of bolus air was introduced into the venous line, an Emboli Detection and Classification system was used to detect and classify GME at the preoxygenator, postoxygenator, and precannula sites. At the same time, real-time pressure and flow data were recorded, and hemodynamic energy was calculated using a custom-made data acquisition system and Labview software. Our results showed that the oxygenator pressure drops of Quadrox-i Adult oxygenator were lower than Capiox RX25 at all flow rates. The Quadrox-i Adult oxygenator retained more hemodynamic energy across the oxygenator. Both oxygenators could trap the majority of GME, but Capiox RX25 did better than the Quadrox-i Adult oxygenator. No GME was delivered to the pseudo patient at all flow rates in the Capiox group. The Capiox RX25 venous reservoir could capture more GME at lower flow rates, while the Quadrox-i Adult venous reservoir performed better at higher flow rates. An open arterial filter purge line reduced GME slightly in the Capiox group, but GME increased in the Quadrox group. The Quadrox-i Adult oxygenator is a low-resistance, high-compliance oxygenator. The GME handling ability of Capiox RX25 performed well under our clinical setting. Further optimized design for the venous/cardiotomy reservoir is needed. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…