Artificial organs
-
The Capiox RX25 and Quadrox-i Adult oxygenators are commonly used in clinical adult cardiopulmonary bypass circuits. This study was designed to test the effectiveness of two adult oxygenators in order to evaluate gaseous microemboli (GME) trapping capability and hemodynamic performance. A simulated adult CPB circuit was used and primed with Ringer's lactate and packed red blood cells (hematocrit 25%). ⋯ The Quadrox-i Adult oxygenator is a low-resistance, high-compliance oxygenator. The GME handling ability of Capiox RX25 performed well under our clinical setting. Further optimized design for the venous/cardiotomy reservoir is needed.
-
Acute renal failure (ARF) is associated with increased mortality in pediatric extracorporeal membrane oxygenation (ECMO). The aim of this study was to identify predictors of ARF during ECMO in pediatric patients after cardiac surgery. A retrospective study analyzed 42 children (≤15 years) after cardiac surgery requiring venous-arterial ECMO between December 2008 and December 2014 at Fuwai Hospital. ⋯ There was a linear correlation between maximum SCr and maximum FHB (Pearson's r = 0.535, P = 0.001). Maximum SCr during ECMO has also a linear correlation with lactate level before initiation of ECMO (Pearson's r = 0.342, P = 0.044). Increased FHB during ECMO and high lactate level before initiation of ECMO were risk factors for ARF during ECMO in pediatric patients after cardiac surgery.