• J Aerosol Med Pulm Drug Deliv · Oct 2013

    Comparative Study

    Targeting aerosol deposition to and within the lung airways using excipient enhanced growth.

    • Geng Tian, P Worth Longest, Xiang Li, and Michael Hindle.
    • 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, VA 23284.
    • J Aerosol Med Pulm Drug Deliv. 2013 Oct 1; 26 (5): 248-65.

    BackgroundPrevious studies have characterized the size increase of combination submicrometer particles composed of a drug and hygroscopic excipient when exposed to typical airway thermodynamic conditions. The objective of this study was to determine the deposition and size increase characteristics of excipient enhanced growth (EEG) aerosols throughout the tracheobronchial (TB) airways and to evaluate the potential for targeted delivery.MethodsSubmicrometer particles composed of a poorly water-soluble drug (insulin) and hygroscopic excipient (sodium chloride) were considered at drug:excipient mass ratios of 50:50 and 25:75. A previously validated computational fluid dynamics model was used to predict aerosol size increase and deposition in characteristic geometries of the mouth-throat (MT), upper TB airways through the third bifurcation (B3), and remaining TB airways through B15. Additional validation experiments were also performed for albuterol sulfate:mannitol particles. Both growth of combination particles and deposition are reported throughout the conducting airways for characteristic slow and deep (SD) and quick and deep (QD) inhalations.ResultsFor all EEG cases considered, MT deposition was less than 1% of the drug dose, which is at least one order of magnitude lower than with state-of-the-art and conventional inhalers. Final aerosol sizes exiting the TB region and entering the alveolar airways were all greater than 3 μm. For SD inhalation, deposition fractions of 20% were achieved in the lower TB region of B8-B15, which is a factor of 20-30×higher than conventional delivery devices. With QD inhalation, maximum alveolar delivery of 90% was observed.ConclusionsIncreasing the dose delivered to the lower TB region by a factor of 20-30×or achieving 90% delivery to the alveolar airways was considered effective aerosol targeting compared with conventional devices. The trend of higher flow rates resulting in better alveolar delivery of aerosols is unique to EEG and may be used to design highly efficient dry powder inhalers.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…