• Military medicine · May 2022

    A Prospective Assessment of a Novel, Disposable Video Laryngoscope With Physician Assistant Trainees Using a Synthetic Cadaver Model.

    • Steven G Schauer, William T Davis, Michelle D Johnson, Mireya A Escandon, Nguvan Uhaa, Joseph K Maddry, Jason F Naylor, Kerri A Van Arnem, and Michael D April.
    • US Army Institute of Surgical Research, JBSA Fort Sam Houston, TX 78234, USA.
    • Mil Med. 2022 May 3; 187 (5-6): e572-e576.

    BackgroundAirway obstruction is the second leading cause of preventable death on the battlefield. Video laryngoscopy has improved airway management in the emergency setting for several decades, and technology continues to improve. Current technology in the supply chain is cost-prohibitive to incorporate at Role 1 facilities, which is where many intubations occur by novice intubators. The i-view is a novel video laryngoscopy device that is handheld, inexpensive, and disposable. The aim of this study was to determine if the i-view is suitable based on performance assessments by physician assistant trainees and survey feedback.Materials And MethodsWe prospectively enrolled physician assistant students at the Interservice Physician Assistant Program at Joint Base San Antonio-Fort Sam Houston. We provided them structured training on how to use the device, and then, a board-certified emergency medicine physician or certified registered nurse anesthetist assessed their intubations performed on a SynDaver mannequin model. We surveyed the participants afterward.ResultsWe enrolled 60 Interservice Physician Assistant Program students. Most participants were male (75%) with a median age of 32 years. Service affiliations included Army (50%), Navy (23%), Air Force (18%), and Coast Guard (8%). Most (70%) had previous deployment experience. All the participants successfully cannulated the mannequins and 98% achieved first-attempt success. Most participants (78%) reported a grade 1 view. On postprocedure survey, 91% strongly agreed with using this device in the deployed setting and 89% strongly agreed with finding it easy to use.ConclusionsAll physician assistant trainees successfully and rapidly performed endotracheal intubation using the disposable i-view video laryngoscope. Study participants rated the device as easy to use and desirable for deployment. Further research is necessary to validate this novel device in the clinical setting before recommending dissemination to the deployed military medical force sets, kits, and outfits.Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2020. This work is written by (a) US Government employee(s) and is in the public domain in the US.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.