- Ashish Jani, Tzlil Rozenblat, Andrew M Yaeh, Tavish Nanda, Shumaila Saad, Yasir H Qureshi, Wenzheng Feng, Michael B Sisti, Jeffrey N Bruce, Guy M McKhann, Jeraldine Lesser, Andrew B Lassman, Steven R Isaacson, and Tony J C Wang.
- ‡Department of Radiation Oncology, §The Taub Institute for Research on Alzheimer's Disease and the Aging Brain, ¶Herbert Irving Comprehensive Cancer, ‖Department of Neurological Surgery, and #Department of Neurology, Columbia University Medical Center, New York, New York.
- Neurosurgery. 2015 Jul 1; 77 (1): 119-25; discussion 125.
BackgroundThe energy index (EI) is a measure of dose homogeneity within a target volume calculated by the integral dose divided by the product of prescription dose and tumor volume.ObjectiveTo assess whether a higher EI is associated with greater local control for brain metastases (BMs) treated by Gamma Knife radiosurgery (GKRS).MethodsWe reviewed all patients treated with GKRS for BM at our institution between January 2009 and February 2014. Data on the prescription dose, prescription isodose line, minimum dose, mean dose, integral dose, tumor volume, and EI were collected. Tumor response was assessed by reviewing follow-up brain imaging studies and classified according to the Response Evaluation Criteria in Solid Tumors. Local control per lesion and dosimetric prognostic factors for local control were assessed by univariate and multivariate Cox proportional hazards regression analyses.ResultsOf 213 patients treated, 126 had follow-up imaging available with a median follow-up of 6 months. Three hundred seventy-three individual tumors were analyzed. Of these, 133 showed a complete response, 157 showed a partial response, 46 remained stable, and 37 developed local failure. Tumors with EI ≥1.6 mJ·mL(-1)·Gy(-1) showed a higher rate of complete response. Local control rates at 6, 11, and 17 months were 95.4%, 86.5%, and 81.5%, respectively. On univariate analysis, the following factors were associated with higher rates of local failure: prescription doses of 16 and 18 Gy compared with a prescription dose of 20 Gy. The following factors were associated with a greater rate of local control: maximum dose and mean dose. On multivariate analysis, the only statistically significant factor associated with a greater rate of local failure was prescription dose of 16 Gy compared with 20 Gy.ConclusionGKRS for BM results in a high rate of local control with an 11-month rate of 86.5%. A higher EI was not significantly associated with a higher rate of local control on multivariate analysis. Prescription dose was found to be the only significant predictor of local control on multivariate analysis.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.