• Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · Jul 2020

    [Feasibility of using esophageal balloon pressure-volume curve to calibrate esophageal pressure during assisted mechanical ventilation].

    • Xiumei Sun, Guangqiang Chen, Yanlin Yang, and Jianxin Zhou.
    • Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing 100070, China. Corresponding author: Zhou Jianxin, Email: zhoujx.cn@icloud.com.
    • Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2020 Jul 1; 32 (7): 808-813.

    ObjectiveTo evaluate the feasibility of esophageal pressure (Pes) calibration by the esophageal balloon pressure-volume (P-V) curve during assisted mechanical ventilation.MethodsA prospective study was conducted. The postoperative patients admitted to intensive care unit of Beijing Tiantan Hospital Affiliated to Capital Medical University from June 2017 to January 2019 who needed pressure support ventilation by tracheal intubation and Pes monitoring with stable breath were enrolled. The Pes monitoring was performed by the esophageal balloon with a small geometric volume (2.8 mL). (1) Balloon volume tests of esophageal balloon were performed by inflating intermittently 0.5 mL increments up to 2.5 mL, the end-expiratory and end-inspiratory Pes were recorded to obtain end-expiratory and end-inspiratory P-V curves. The intermediate section in end-expiatory P-V curve that showed linear correlation was identified (as intermediate linear section), whose volume range was balloon working volume (Vwork) and slope was esophageal wall elastance (Ees), the balloon volume with the largest difference between end-expiratory and end-inspiratory Pes was the best balloon volume (Vbest), and the product of Ees and Vbest was esophageal wall recoil pressure reacting to balloon filling. To minimize the effect of esophageal wall on Pes, the calibrated Pes was the difference of Pes and esophageal wall recoil pressure. The consistency of calibrated Pes obtained by balloon volume at Vbest and other Vwork were analyzed. (2) For the convenience of clinical application, a simplified method was introduced to calibrate Pes. Based on all Vwork of patients located in 0.5-1.5 mL, the difference of end-expiratory Pes between balloon volume at 0.5 mL and 1.5 mL divided by 1.0 mL was used to estimate Ees, and the Pes among 0.5-1.5 mL was calibrated by Ees obtained by the simple method. The consistency of calibrated Pes obtained by the simple method and standard method were observed.ResultsTotally 30 patients were enrolled, all end-expiratory and end-inspiratory P-V curves existed the intermediate linear section, the calibrated Pes at Vwork did not increase with the balloon being inflated and had a good consistency with the calibrated Pes at Vbest, mean difference and 95% confidence interval (95%CI) was -0.02 (-1.50-1.50) cmH2O (1 cmH2O = 0.098 kPa). The Ees and calibrated Pes estimated by the simple method had a good agreement with the standard method, mean difference and 95%CI was -0.2 (-1.0-0.6) cmH2O/mL and 0.2 (-1.1-1.4) cmH2O, respectively.ConclusionsDuring assisted mechanical ventilation, the use of a small geometric volume esophageal balloon to monitor Pes and balloon P-V curve to calibrate Pes is feasible. The simple method can be used for simplifying clinical application, that's only by monitoring Pes at balloon volume at 0.5, 1.0 and 1.5 mL to evaluate the Ees and calibrate Pes.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…