• Int. J. Clin. Pract. · May 2021

    Free Triiodothyronine to Free Thyroxine Ratio in the Differential Diagnosis of Thyrotoxicosis and Hyperthyroidism: A Retrospective Study.

    • Çiğdem Tura Bahadır, Merve Yılmaz, and Elif Kılıçkan.
    • Department of Endocrinology and Metabolism, Faculty of Medicine, Amasya University, Amasya, Turkey.
    • Int. J. Clin. Pract. 2021 May 1; 75 (5): e14003.

    BackgroundThyroid ultrasound, thyroid scintigraphy and radioactive iodine uptake (RAIU) tests are helpful in the differential diagnosis of thyrotoxicosis and hyperthyroidism. In the setting where these techniques are unavailable or unusable more accessible, and cheaper techniques would be helpful.AimsWe evaluated the capability of free triiodothyronine to free thyroxine ratio (FT3/FT4) to differentiate Graves' Disease (GD) and destructive thyroiditis (DT).MethodsIn total, 318 patients with GD and 140 patients with DT were included in the study. Patients were assigned to two groups: GD and DT (subacute thyroiditis, painless thyroiditis, postpartum thyroiditis). Serum thyroid-stimulating hormone (TSH), FT4, FT3 levels and FT3/FT4 ratio were evaluated in each group. To obtain the optimal diagnostic cut-off value of FT3, FT4 and FT3/FT4 ratio, ROC curve analysis was performed of all untreated thyrotoxicosis patients.ResultsThe optimal FT3/FT4 ratio cut-off value was 2.96, with a sensitivity of 71.7%, the specificity of 88.6%. The area under the ROC curve of the FT3/FT4 ratio regarding the diagnosis of GD was 0.864 (95% CI: 0.830-0.894). The cut-off level of FT3 for GD was determined as 6.6 pg/mL which had a sensitivity of 72.3% and specificity of 68.6% (AUC = 0.771 P < .001). The cut-off level of FT4 for GD was determined as 3.65 ng/dl with a sensitivity of 35.5% and specificity of 83.6% (AUC = 0.615 P < .001). When a high specificity is needed, FT3/FT4 cut-off value increases to 3.63 with 99.3% specificity and 36.5% sensitivity.ConclusionsFT3/FT4 ratio helps distinguish GD and DT. In cases of situations where RAIU/scintigraphy and TRAb cannot be studied, the FT3/FT4 ratio is a viable diagnostic tool. Cut-off values with higher specificity can be more helpful in differential diagnosis of GD.© 2021 John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…