-
J Clin Monit Comput · Jun 2013
Comparative Study Observational StudyCardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo.
- Sophie Marqué, Antoine Gros, Loic Chimot, Arnaud Gacouin, Sylvain Lavoué, Christophe Camus, and Yves Le Tulzo.
- Service de Réanimation Médico-Chirurgicale, Centre Hospitalier Sud Francilien, 116 boulevard Jean Jaurès, 91106 Corbeil Essonnes, France. sophie.marque@ch-sud-francilien.fr
- J Clin Monit Comput. 2013 Jun 1;27(3):273-9.
AbstractContinuous cardiac index (CI) monitoring is frequently used in critically ill patients. Few studies have compared the pulse contour-based device FloTrac/Vigileo to pulmonary artery thermodilution (PAC) in terms of accuracy for CI monitoring in septic shock. The aim of our study was to compare the third-generation FloTrac/Vigileo to PAC in septic shock. Eighteen patients with septic shock requiring monitoring by PAC were included in this study. We monitored CI using both FloTrac/Vigileo and continuous thermodilution (PAC-CI). Hemodynamic data were recorded every hour or every 2 min during fluid challenges. The primary endpoint was the global agreement of all CI-paired measurements determined using the Bland-Altman method adapted to replicated data. We tested the linearity of the bias by regression analysis, and compared the reactivity of the 2 techniques during fluid challenges. A receiver operating characteristic (ROC) curve analysis tested the ability of FloTrac/Vigileo to detect concordant and significative CI changes, using PAC-CI as the reference method. Overall, 1,201 paired CI measurements were recorded. The Bland-Altman analysis for global agreement of the 2 techniques showed a bias of -0.1 ± 2.1 L min(-1) m(-2) and a percentage error of 64 %. The overall correlation coefficient between PAC-CI and FloTrac/Vigileo CI was 0.47 (p < 0.01), with r(2) = 0.22. The area under the curve of the ROC curve for detecting concordant and significant changes in CI was 0.72 (0.53; 0.87). In our study, third-generation Flowtrac-Vigileo appears to be too inaccurate to be recommended for CI monitoring in septic shock.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.