• Orthop Traumatol Sur · Dec 2019

    Comparative Study

    Clinical evaluation of double-plate osteosynthesis for olecranon fractures: A retrospective case-control study.

    • Alexander Ellwein, Konstantinos Argiropoulos, Rony-Orijit DeyHazra, Marc-Frederic Pastor, Tomas Smith, and Helmut Lill.
    • Department for Orthopaedic Surgery, Medical School Hannover, DIAKOVERE Annastift, Anna-von-Borries-Straße 1-7, 30625 Hannover, Germany; Department for Orthopaedic Surgery and Traumatology, DIAKOVERE Friederikenstift, Humboldtstr 5, 30169 Hannover, Germany. Electronic address: alexander.ellwein@diakovere.de.
    • Orthop Traumatol Sur. 2019 Dec 1; 105 (8): 1601-1606.

    IntroductionSingle, dorsal plating is a commonly used technique for treating olecranon fractures. Double-plate osteosynthesis is an alternative treatment. Aim of this study was to present the surgical technique using this novel double-plate implant for olecranon fractures and review clinical results, complication rates and revision surgeries. Results were compared to single, dorsal plating.HypothesisDoes double-plate osteosynthesis for olecranon fractures improve material's tolerance with respect to osteosynthesis by single dorsal plating?Patients And MethodsBetween February 2011 and March 2015, we retrospectively evaluated 47 patients who were included in this study: 25 were treated with a low-profile double-plate osteosynthesis and 22 with an anatomically pre-shaped 3.5mm locking compression plate (LCP). The 2 groups were the result of a change of implants in our department in 2013. Patient satisfaction, range of motion, patient related outcome scores (Mayo Elbow Performance Score [MEPS], Disabilities of Arm, Shoulder and Hand Score [DASH]), complications and revision surgeries were evaluated. Results between both implant types were statistically compared using the Mann-Whitney U test.ResultsAfter a mean follow-up of 41 months (range: 25-61), the low-profile double-plate group showed a range of motion of 127°, MEPS of 94 and DASH of 6. The 3.5mm LCP group was found to have a range of motion of 130°, MEPS of 96 and DASH of 8. No clinical difference was found between groups. A total of 9 revision surgeries after double-plate osteosynthesis were recorded including seven implant removals and two intraarticular screws. One loosening of a screw without revision surgery was reported. The 3.5mm LCP group had 9 revision surgeries including eight implant removals and one intraarticular screw.DiscussionLow-profile double-plate osteosynthesis is a safe and effective alternative treatment of olecranon fractures. Subjective and objective clinical outcome measures revealed a low complication rate and excellent results. Still, implant removal due to soft tissue irritation remains an issue. These findings were comparable to common dorsal plate osteosynthesis.Level Of EvidenceIII, retrospective case-control study.Copyright © 2019 Elsevier Masson SAS. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…