• Curēus · Feb 2019

    Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound.

    • Kamran Munawar, Muhammad Tariq Khan, Syed Waqar Hussain, Aayesha Qadeer, Zahid Siddique Shad, Sheher Bano, and Azmat Abdullah.
    • Internal Medicine, Shifa International Hospital, Islamabad, PAK.
    • Cureus. 2019 Feb 27; 11 (2): e4145.

    AbstractBackground The early detection of elevated intracranial pressure (ICP) can not only prevent mortality but also aid in more aggressive management. Brain computed tomography (CT) is a mainstay modality in detecting elevated ICP, but the feasibility of using brain CTs to detect elevated ICP in critically ill patients is limited, especially for patients who require high levels of inotropic support. The optic nerve sheath is a direct extension of the brain meninges. Therefore, the elevation of ICP is directly transmitted to the sheath. Measuring the optic nerve sheath diameter (ONSD) through ultrasound (US) is a bedside, noninvasive means to detect elevated ICP. The goal of this study was to assess the correlation of ONSD with elevated ICP as measured via US in an intensive care unit (ICU). Methods We conducted a six-month prospective, single-center, observational study of mass effect stroke patients aged 18 to 65 years who had a traumatic brain injury (TBI) and were admitted to the ICU. Patients with chronic hydrocephalus, extensive local orbit trauma, a pre-existing ocular disease affecting the optic nerve and/or orbital cavity, hyperthyroidism with exophthalmos, and facial trauma affecting the orbits and/or eyeballs were excluded. We measured the ONSD at the entry of optic nerve into the globe using two-dimensional (2D) US. Results One hundred patients were included in the study. Forty-nine patients had diffuse cerebral edema detected on CT scan correlating with increased ONSD notable via bedside US. The mean ONSD related to CT-detectable elevated ICP was 0.61 cm. The sensitivity for the ONSD cut-off value of ≥5.8 mm was 94% (95% confidence interval [CI], 84.05% to 98.79%), and the specificity was 96.08% (95% CI, 86.7% to 99.52%).The positive predictive value was 92.08% (95% CI, 86.28% to 98.96%), and the negative predictive value was 94.23% (95% CI, 84.47% to 98.00%). Conclusion The greatest accuracy in ONSD was found with a cut-off of >0.58 cm in patients with positive CT brain findings. Therefore, US can be used as an initial screening test when physicians suspect a patient has elevated ICP.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…