Experience with a standardized protocol to predict successful explantation of left ventricular assist devices.
- Yuriy Hrytsyna, Simon Kneissler, Friedrich Kaufmann, Marcus Müller, Felix Schoenrath, Johanna Mulzer, Simon H Sündermann, Volkmar Falk, Evgenij Potapov, and Jan Knierim.
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany.
- J. Thorac. Cardiovasc. Surg. 2022 Dec 1; 164 (6): 19221930.e21922-1930.e2.
ObjectivePatients with a continuous-flow left ventricular assist device may show recovery of myocardial function with unloading. Identifying candidates for and predicting clinical and hemodynamic stability after left ventricular assist device explantation remain challenging.MethodsRetrospective analysis of patients who underwent evaluation for left ventricular assist device explantation following a standardized protocol from January 2016 to March 2020. Patients who met screening criteria underwent echocardiography under "baseline," "minimal net flow," and "pump stop" conditions. If the protocol criteria were met, right heart catheterization with left ventricular assist device stoppage and occlusion of the outflow graft with a balloon catheter were performed. In patients with pulmonary capillary wedge pressure less than 16 mm Hg, explantation was performed under "pump stop" conditions.ResultsA total of 544 patients were screened. Of these, 57 (10.5%) underwent a total of 73 echocardiography under "baseline" "minimal net flow" and "pump stop" conditions and 46 underwent left ventricular assist device stoppage and occlusion of the outflow graft with balloon catheter maneuvers. Complications during the procedure were rare. Ultimately, 21 patients (3.9%) underwent explantation. The left ventricular ejection fraction at baseline was 55.5% ± 6.5%. The mean pulmonary capillary wedge pressure was 8.1 ± 2.6 mm Hg and increased to 10.7 ± 2.9 mm Hg under left ventricular assist device stoppage and occlusion of the outflow graft with a balloon catheter. A nonischemic cause of cardiomyopathy was more likely to be found in patients who underwent explantation (20/21 patients [95%], P = .020). The survival 1 year after explantation was 95.2%, with 1 death occurring 222 days after left ventricular assist device explantation. At follow-up (median 24.9 months [interquartile range, 16.4-43.1 months]), patients were in New York Heart Association class 1 (61.9%), 2 (28.6%), and 3 (9.5%).ConclusionsOur 4-year experience with a standardized protocol for left ventricular assist device explantation showed a low rate of adverse events. If all criteria are met, explantation can be performed safely and with an excellent survival and functional class.Copyright © 2021 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.