• Arch Orthop Trauma Surg · Jun 2014

    ACL double bundle linked cortical-aperture tibial fixation: a technical note.

    • John Nyland, Yee Han Dave Lee, Mark McGinnis, Shane Kibbe, Yavuz Kocabey, and David N M Caborn.
    • Division of Sports Medicine, Department of Orthopaedic Surgery, University of Louisville, Louisville, KY, 40202, USA, jnyland@spalding.edu.
    • Arch Orthop Trauma Surg. 2014 Jun 1;134(6):835-42.

    IntroductionThe purpose of this technical note is to describe the tibial fixation characteristics for an all-inside anatomic anterior cruciate ligament (ACL) reconstruction method that links extra-cortical button suspensory and aperture fixation replicating double bundle soft tissue graft function in single femoral and tibial sockets.Materials And MethodsA 55° drill guide aligned guidewires in the ACL footprint center of 8 porcine tibiae (mean apparent bone mineral density = 1.15 g/cm(2)). A Flipcutter created 27 mm sockets and 15 mm guidewire channels. Advancement sutures seated porcine soft tissue graft-PEEK implants to achieve both socket aperture and extra-cortical button suspensory fixation. Potted specimens were loaded into a 6º of freedom clamp with the servohydraulic loading vector in direct socket alignment. Constructs were pre-loaded to 25 N, underwent 10 pre-conditioning cycles (0-50 N, 0.5 Hz), and 500 submaximal loading cycles (50-250 N, 1 Hz) prior to load to failure testing (20 mm/min). Mode of failure was recorded. Descriptive statistical analysis was performed.ResultsAll specimens survived the biomechanical test protocol. Displacement during cyclic loading was 2.8 ± 0.9 mm, yield load was 475.2 ± 36 N, ultimate load at failure was 671.4 ± 98 N, stiffness was 127.5 ± 15 N/mm. The most common failure mode was suture pulling through the soft tissue graft.ConclusionsThis ACL reconstruction method combines the high ultimate load to failure and low graft slippage of extra-cortical button suspensory fixation with the high stiffness of aperture fixation. Biomechanical test findings were comparable or better to previous reports for displacement during submaximal loading, ultimate failure load, and construct stiffness. Based on current understanding of soft tissue graft ACL reconstruction biomechanics, this fixation method should enhance graft-bone socket integration during healing, facilitate long-term graft survival, and improve patient outcomes. Clinical studies are needed to confirm in vivo efficacy.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…