• J Anal Toxicol · Oct 2019

    Validation of an LC-MS/MS Method for the Quantification of 13 Designer Benzodiazepines in Blood.

    • Victoria Mei, Marta Concheiro, Justine Pardi, and Gail Cooper.
    • Department of Sciences, John Jay College of Criminal Justice, City University of New York, 524 W 59th St, New York, NY 10019, USA.
    • J Anal Toxicol. 2019 Oct 17; 43 (9): 688-695.

    AbstractThe misuse of designer benzodiazepines, as an alternative to prescription benzodiazepines and for drug-facilitated sexual assaults, has emerged as a growing threat, due in part to the ease of purchasing these drugs on the internet at low prices. Causing concern for safety is the lack of dosage information resulting in users self-medicating, often leading to unintended overdoses, coma or death at higher doses. With limited published data regarding the quantification of designer benzodiazepines in forensic cases, a method was validated for the determination of 13 designer benzodiazepines in postmortem blood, to add to the in-house method that already included a limited number of common designer benzodiazepines. The developed method included 3-hydroxyphenazepam, clobazam, clonazolam, delorazepam, deschloroetizolam, diclazepam, flualprazolam, flubromazepam, flubromazolam, flunitrazolam, meclonazepam, nifoxipam and pyrazolam in 0.5 mL postmortem blood using liquid chromatography-tandem mass spectrometry. The analytes were treated with solid phase extraction before undergoing separation on a C18 column and analyzed on the mass spectrometer in electrospray positive mode using multiple reaction monitoring. The linear range of the calibration curve was 1-200 ng/mL and up to 500 ng/mL for 3-hydroxyphenazepam, clobazam, flubromazepam and pyrazolam. The limits of detection and quantitation were 0.5 ng/mL (signal-to-noise ratio >3) and 1 ng/mL, respectively. The calculated bias, intra-day imprecision, relative standard deviation (RSD) and inter-day imprecision RSD were ±12%, 3-20% and 4-21%. Matrix effects ranged from -52% to 33% with RSD values ranging from 3-20%, indicating consistent effects throughout multiple sources. Recovery ranged from 35 to 90%, where only two compounds were <50%. Other parameters tested included carryover, stability, interference and dilution integrity, which all yielded acceptable results. With the application of this method to blood specimens from the New York City Office of Chief Medical Examiner, this validated method proved to be simple, reproducible, sensitive and robust.© The Author(s) 2019. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…