-
- Ethan J Halpern, Eric L Gingold, Hugh White, and Katrina Read.
- Department of Radiology, Thomas Jefferson University, 132 South 10th Street, Philadelphia, PA 19107-5244. Electronic address: ethan.halpern@jefferson.edu.
- Acad Radiol. 2014 Jun 1; 21 (6): 805-11.
Rationale And ObjectivesTo evaluate knowledge-based iterative model reconstruction (IMR) to improve image quality and reduce radiation dose in coronary computed tomography angiography (cCTA).Materials And MethodsWe evaluated 45 consecutive cCTA studies, including 25 studies performed with an 80% systolic dose reduction using tube current modulation (TCM). Each study was reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (iDose(4)), and IMR in a diastolic phase. Additional systolic phase reconstructions were obtained for TCM studies. Mean pixel attenuation value and standard deviation (SD) were measured in the left ventricle and left main coronary artery. Subjective scores were obtained by two independent reviewers on a 5-point scale for definitions of contours of small coronary arteries (<3 mm), coronary calcifications, noncalcified plaque, and overall diagnostic confidence for the presence/absence of stenosis.ResultsThere was no significant difference in pixel intensity among FBP, iDose(4), and IMR (P > .8). For diastolic phase images, noise amplitude in the left main coronary artery was reduced by a factor of 1.3 from FBP to iDose(4) (SD = 99 vs. 74; P = .005) and by a factor of 2.6 from iDose(4) to IMR (SD = 74 vs. 28; P < .001). For systolic phase TCM images, noise amplitude in the left main coronary artery was reduced by a factor of 2.3 from FBP to iDose(4) (SD = 322 vs. 142; P < .001) and by a factor of 3.0 from iDose(4) to IMR (SD = 142 vs. 48; P < .001). All four subjective image quality scores were significantly better with IMR compared to iDose(4) and FBP (P < .001). The reduction in image noise amplitude and improvement in image quality scores were greatest among obese patients.ConclusionsIMR reduces intravascular noise on cCTA by 86%-88% compared to FBP, and improves image quality at radiation exposure levels 80% below our standard technique.Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.