• Spine · Aug 2012

    Clinical Trial

    Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system.

    • Kalil G Abdullah, Frank S Bishop, Daniel Lubelski, Michael P Steinmetz, Edward C Benzel, and Thomas E Mroz.
    • Cleveland Clinic Lerner College of Medicine, Cleveland, OH 44195, USA.
    • Spine. 2012 Aug 1;37(17):E1074-8.

    Study DesignA prospective clinical research article.ObjectiveThe primary goals were to determine (1) radiation exposure to the spine surgeon with the use of an intraoperative 3-dimensional imaging system and (2) to define the safe distance from the computed tomographic scanner.Summary Of BackgroundIntraoperative radiation exposure to the spinal surgeon has been assessed during 2-dimensional fluoroscopy but has not been investigated during intraoperative 3-dimensional imaging.MethodsTen patients undergoing lumbar or thoracolumbar fusion were enrolled in a prospective trial to determine the radiation exposure to a spine surgeon standing in the substerile room, with the use of the O-ARM Imaging System (Medtronic, Memphis, TN). A thermolucent digital dosimeter was worn at chest level without a lead apron. Dosimeter readings and distance from the spine surgeon were recorded. RESULTS.: Average surgeon exposure was 44.22 ± 17.4 μrem (range: 17.71-70.76 μrem). The mean distance from the O-ARM was 4.56 ± .32 m, and the surgeon was exposed for an average of 19.6 ± 5.7 seconds (range: 8.05-28.7 s). The annual number of necessary procedures required to surpass the exposure limit, according to the data presented here, would be 113,071 operations using O-ARM. Hence, the number of necessary procedures for O-ARM use is predicted to be 1,130,710 annual procedures to reach the occupational exposure limits for extremity, skin, and all other organs and 339,213 procedures to reach the limits for the lens of eye.ConclusionRadiation exposure is minimal to the surgical team during routine use of the O-ARM imaging system. The number of procedures required to surpass occupational exposure limits is high if using appropriate distance from the O-ARM.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…