• Spine · Aug 2012

    An injectable nucleus pulposus implant restores compressive range of motion in the ovine disc.

    • Neil R Malhotra, Woojin M Han, Jesse Beckstein, Jordan Cloyd, Weiliam Chen, and Dawn M Elliott.
    • Department of Neurological Surgery, University of Pennsylvania, Philadelphia PA 19106, USA. neil.malhotra@uphs.upenn.edu
    • Spine. 2012 Aug 15;37(18):E1099-105.

    Study DesignInvestigation of injectable nucleus pulposus (NP) implant.ObjectiveTo assess the ability of a recently developed injectable hydrogel implant to restore nondegenerative disc mechanics through support of NP functional mechanics.Summary Of Background DataAlthough surgical intervention for low back pain is effective for some patients, treated discs undergo altered biomechanics and adjacent levels are at increased risk for accelerated degeneration. One potential treatment as an alternative to surgery for degenerated disc includes the percutaneous delivery of agents to support NP functional mechanics. The implants are delivered in a minimally invasive fashion, potentially on an outpatient basis, and do not preclude later surgical options. One of the challenges in designing such implants includes the need to match key NP mechanical behavior and mimic the role of native nondegenerate NP in spinal motion.MethodsThe oxidized hyaluronic acid gelatin implant material was prepared. In vitro mechanical testing was performed in mature ovine bone-disc-bone units in 3 stages: intact, discectomy, and implantation versus sham. Tested samples were cut axially for qualitative structural observations.ResultsDiscectomy increased axial range of motion (ROM) significantly compared with intact. Hydrogel implantation reduced ROM 17% (P < 0.05) compared with discectomy and returned ROM to intact levels (ROM intact 0.71 mm, discectomy 0.87 mm, postimplantation 0.72 mm). Although ROM for the hydrogel implant group was statistically unchanged compared with the intact disc, ROM for sham discs, which received a discectomy and no implant, was significantly increased compared with intact. The compression and tension stiffness were decreased with discectomy and remained unchanged for both implant and sham groups as expected because the annulus fibrosus was not repaired. Gross morphology images confirmed no ejection of NP implant.ConclusionAn injectable implant that mimics nondegenerate NP has the potential to return motion segment ROM to normal subsequent to injury.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…