    Study DesignA prospective cohort study.ObjectiveTo determine serum titanium, niobium, and aluminum levels in pediatric patients within the first postoperative year after instrumented spinal arthrodesis.Summary Of Background DataInstrumented spinal arthrodesis is a common procedure to correct scoliosis and kyphosis. Titanium-based instrumentation is increasingly favored due to enhanced biomechanical properties, but concerns have arisen regarding metal debris release and the potential for local and systemic complications.MethodsThe pattern of systemic metal release over time was evaluated by measuring serum titanium, niobium, and aluminum levels preoperatively and 1 week, 1 month, 6 months, and 12 months after instrumented spinal arthrodesis using a titanium alloy. Serum metal levels were measured using high-resolution inductively coupled plasma mass spectrometry.ResultsThirty-two patients were included in the study group. Mean age at surgery was 14.7 years. Preoperative and postoperative concentrations of serum titanium and niobium were significantly different (P = 0.0001). Median postoperative serum concentrations of titanium and niobium were elevated 2.4- and 5.9-fold above the normal range respectively with 95% and 99% of samples elevated postoperatively. A significant and rapid rise in serum titanium and niobium levels was observed within the first postoperative week, after which elevated serum levels persisted up to 12 months.ConclusionWe report abnormally elevated serum titanium and niobium levels in patients with titanium-based spinal instrumentation up to 12 months. The long-term systemic consequences of debris generated by wear and corrosion of spinal instrumentation is unclear but concerning, particularly as these implants inserted into the pediatric population may remain in situ for beyond 6 decades.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…