• Spine · Apr 2013

    Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study.

    • Yong Ahn, Chang-Ho Kim, June Ho Lee, Sang-Ho Lee, and Jin-Sung Kim.
    • Department of Neurosurgery, Wooridul Spine Hospital, Seoul, Korea. ns-ay@hanmail.net
    • Spine. 2013 Apr 1;38(7):617-25.

    Study DesignA prospective study.ObjectiveThe purpose of this study was to determine the radiation dose to which the surgeons are exposed during percutaneous endoscopic lumbar discectomy (PELD) and to calculate the allowable number of cases per year.Summary Of Background DataTransforaminal PELD is a minimally invasive technique for soft disc herniation. Minimal invasiveness can be achieved through the use of fluoroscopy and endoscopy. The radiation dose to the surgeon during PELD is unknown.MethodsThe occupational radiation dose absorbed by 3 spinal surgeons performing 30 consecutive PELDs (33 levels) during a 3-month period was evaluated. Transforaminal PELDs were performed according to the standard technique. The radiation exposure of the neck, chest, arm, and both hands of the surgeons was measured. Occupational exposure guidelines of National Council on Radiation Protection & Measurements were used to calculate the allowable number of procedures per year.ResultsThe mean operation time was 49.8 minutes, and the mean fluoroscopy time was 2.5 minutes. No significant correlations were found between operation time and fluoroscopy time. The calculated radiation doses per operated level were as follows: neck, 0.0785 mSv; chest, 0.1718 mSv; right upper arm, 0.0461 mSv; left ring finger, 0.7318 mSv; and right ring finger, 0.6694 mSv. The protective effects of a lead collar and lead apron were demonstrated by the reduction of the radiation dose by 96.9% and 94.2%, respectively. Therefore, with regard to whole-body radiation, 5379 operations can be performed per year using a lead apron, whereas only 291 operations can be performed without using a lead apron. Moreover, 1910 operations can be performed within the occupational exposure limit for the eyes (150 mSv), and 683 operations can be performed within the occupational exposure limit for the hands (500 mSv).ConclusionWithout radiation shielding, a surgeon performing 291 PELDs annually would be exposed to the maximum allowable radiation dose. Given the measurable lifetime radiation hazards to the surgeon, the use of adequate protective equipment is essential to reducing exposure during PELD.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…