• Ann Fr Anesth Reanim · Jan 1995

    Comparative Study

    [Measurement of tympanic temperature by infrared and thermocouple thermometry. A comparative study].

    • N Nathan, A Guillaume, and P Feiss.
    • Ann Fr Anesth Reanim. 1995 Jan 1; 14 (4): 336-9.

    ObjectiveTo compare tympanic temperatures obtained with an infrared thermometer Core Check 2090A (IVAC), non in contact with the tympanic membrane, to values obtained with a thermocouple thermometer Mon-A-Therm (Mallinckrodt) in contact with it, and to assess whether the differences depend on the person measuring the temperature.Study DesignProspective comparative open study.PatientsThe study included 150 adults in whom the tympanic temperatures were measured at their admission to recovery room by 10 nurse anaesthetists.MethodsEach thermometer was inserted in the same patient into an external acoustic meatus. The median and range of the temperature differences were used to assess the bias and the accuracy of the measures. Their reliability was analyzed with consideration of the measuring person and the presence of irrelevant values, defined as a temperature difference over 0.3 degrees C.ResultsThe temperatures obtained with both devices were similar (36.2 +/- 0.7 degrees C with IVAC thermometer vs 36.2 +/- 0.8 degrees C with Mallinckrodt thermometer). The median value of the differences was 0 degrees C, with a range of 2.5 degrees C (maximum value + 1.5 degrees C, minimum value: -1 degree C). Nineteen patients could be qualified as hypothermic (temperature < 36.5 degrees C) with one thermometer and normothermic (temperature > or = 36.5 degrees C) with the other. Among them, only 9 (6%) had temperature differences above 0.3 degrees C. The temperature differences were not different according to the measuring nurse. Nevertheless two of them obtained major differences or irrelevant figures.ConclusionsAs compared to the thermocouple thermometry, infrared thermometry has no bias but a low precision. The measurement error does not allow the recognition of hypothermia in 6% of patients. The error may be made by the measuring person and/or related to the anatomy and the patency of the external acoustic meatus. Tympanic infrared thermometry seems to be a convenient method for temperature measurements at short time intervals in the recovery room, provided its limitations are kept in mind.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.