-
J. Thromb. Haemost. · Aug 2016
Factor VIII chromogenic assays can be used for potency labeling and postadministration monitoring of N8-GP.
- W Pickering, M Hansen, M Kjalke, and M Ezban.
- Novo Nordisk A/S, Novo Nordisk Park, 2760, Måløv, Denmark.
- J. Thromb. Haemost. 2016 Aug 1; 14 (8): 1579-87.
UnlabelledEssentials Chromogenic assays may be less variable than one-stage clot assays for measuring modified factor VIII. Chromogenic assays were evaluated for N8-GP potency labeling and postadministration monitoring. There was no significant difference between chromogenic assay kits for measuring N8-GP potency. Postadministration monitoring of N8-GP was comparable to turoctocog alfa for all kits tested.SummaryBackground Factor VIII activity (FviiiC) is commonly measured using one-stage activated partial thromboplastin time (aPTT)-based clot assays. Chromogenic assays are, however, an alternative, and potency assessment in Europe is performed using chromogenic assays. One-stage clot assays are in general associated with high variability, and modified FVIII products may add to this variability. FVIII chromogenic assays may be less affected. Objectives To evaluate available chromogenic assay kits for potency labeling of polyethylene glycol-glycoconjugated turoctocog alfa (turoctocog alfa pegol [N8-GP]) and to evaluate selected chromogenic kits for postadministration monitoring of N8-GP using turoctocog alfa (Novoeight(®) ) as comparator. Methods Six FVIII chromogenic assay kits were adapted to the European Pharmacopeia guidelines for potency labeling, including assessment of time to 50% FX activation. Four kits were adapted for postadministration monitoring using an ACL(®) TOP 500 analyzer. Severe hemophilia A plasma was spiked with N8-GP or turoctocog alfa to simulate postadministration samples. The World Health Organization (WHO) 8th International Standard (IS) FVIII concentrate was used as calibrator throughout. In addition, a plasma calibrator was used for postadministration samples. Results When measuring N8-GP potency, no significant difference using a 1% significance level was observed between kits. In simulated postadministration samples, all test kits were highly accurate and precise, except at low concentrations, with no significant difference betweenFviiiC (P > 0.05) measured using the different calibrators. However, values obtained using the WHO 8th IS were closer to labeled values. Conclusions Chromogenic assay kits tested measured consistentFviiiC for N8-GP potency and showed comparable results for N8-GP and turoctocog alfa in simulated postadministration samples.© 2016 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.