    Study DesignA retrospective cohort study reporting the use of intraoperative computed tomography (CT) and image-guided navigation system for the placement of pedicle screws in pediatric compared with adult patients.ObjectiveTo evaluate the accuracy of open pedicle screw placement in pediatric patients using intraoperative CT and 3-dimensional (3D) image-guided navigation.Summary Of Background DataPedicle screws are widely used in children for the correction of spinal deformity. Navigation systems and intraoperative CT are now available as an adjunct to fluoroscopy and anatomic techniques for placing pedicle screws and verifying screw position.MethodsFrom 2007 to 2010, 984 pedicle screws were placed in a consecutive series cohort of 50 pediatric patients for spinal deformity correction with the use of intraoperative CT (O-arm, Medtronic, Inc, Louisville, CO) and a computerized navigation system (Stealth, Medtronic, Inc, Louisville, CO). The primary outcome measure for this study is redirection or removal of screw on the basis of the intraoperative CT imaging. During the study period, 1511 screws were placed in adult patients using the same image guidance system.ResultsA total of 984 pedicle screws were implanted using real-time navigation, with a mean of 20 screws per patient (range: 2-34). On the basis of intraoperative CT, 35 screws (3.6%) were revised (27 redirected and 8 removed), representing a 96.4% accuracy rate. No patients returned to the operating room because of screw malposition.Of the 1511 screws placed in adult patients, 28 (1.8%) were revised intraoperatively for malposition on CT imaging, for an overall 98.2% accuracy rate. Screw revision thus was more common in the pediatric population (P = 0.008). However, the pediatric screw accuracy rate is significantly higher than the findings from a recent meta-analysis of predominantly nonnavigated screws in children, reporting a 94.9% accuracy rate (P = 0.03).ConclusionWe report 96.4% accuracy in pediatric pedicle screw placement using intraoperative CT and a 3D navigation system. This is similar to other reports and has better accuracy than a recent meta-analysis of nonnavigated screws in children.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…