Randomized Controlled Trial Multicenter Study
Reduction of inappropriate ICD therapies in patients with primary prevention of sudden cardiac death: DECREASE study.
- Jörg Otto Schwab, Hendrik Bonnemeier, Thomas Kleemann, Johannes Brachmann, Sven Fischer, Frank Birkenhauer, and Frank Eberhardt.
- Cardiology, Beta Klinik, Joseph-Schumpeter-Allee 15, Bonn, 53227, Germany. schwab@betaklinik.de.
- Clin Res Cardiol. 2015 Dec 1; 104 (12): 1021-32.
BackgroundA significant number of patients with an implantable cardioverter/defibrillator (ICD) for primary prevention receive inappropriate shocks. Previous studies have reported a reduction of inappropriate therapies with simple modifications of ICD detection settings, however, inclusion criteria and settings varied markedly between studies. Our aim was to investigate the effect of raising the ICD detection zone in the entire primary prevention ICD population.Methods And Results543 patients receiving an ICD for primary prevention were randomized to either conventional or progressive ICD programming. The detection rate was programmed at 171 bpm for ventricular tachycardia (VT) and 214 bpm for ventricular fibrillation (VF) in the Conventional group and 187 bpm for VT and 240 bpm for VF in the Progressive group. 43 % of patients received single-chamber and 57 % dual-chamber detection devices (DDD-ICD 19 %; CRT-D 38 %). The primary endpoint consisted of inappropriate therapies and untreated VT/VF. The primary endpoint was reached in 35 patients (13 %) in the Conventional group and 17 patients (6 %) in the Progressive group (p = 0.004). Progressive ICD programming led to significantly fewer amount of patients with ICD therapies (26 vs. 14 %; p < 0.001) and shocks (11 vs. 5 %; p = 0.023) compared to conventional ICD programming. Sub-analyses showed the greatest reduction of inappropriate therapies and shocks in dual-chamber detection devices with progressive compared to single-chamber detection devices with conventional ICD programming (p < 0.001).ConclusionsProgressive ICD programming reduces the number of inappropriate therapies and shocks in a broad primary prevention ICD population particularly in combination with dual-chamber detection algorithms.Clinical Trial Registrationhttp://clinicaltrials.gov ; ClinicalTrials.gov identifier NCT01217528.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.