Volatile anesthetic gas concentration sensing using flow sensor fusion for use in Austere settings.
- Patrick R Kolbay, Joseph A Orr, and Kai Kück.
- Department of Anesthesiology, University of Utah School of Medicine, Salt Lake City, UT, 84132, USA. patrick.kolbay@utah.edu.
- J Clin Monit Comput. 2022 Jun 1; 36 (3): 725-733.
AbstractFlow sensors are often sensitive to the presence of volatile anesthetics. However, this sensitivity provides a unique opportunity to combine flow sensors of differing technological principles as an alternative to measuring volatile anesthetic gas concentration, particularly for austere settings. To determine the feasibility of flow sensor fusion for volatile anesthetic concentrations monitoring, eight flow sensors were tested with isoflurane, sevoflurane, and desflurane, ranging in concentrations from 0-4.5%, 0-3.5%, and 0-18%, respectively. Pairs of flow sensors were fit to the volatile anesthetic gas concentration with a leave-one-out cross-validation method to reduce the likelihood of overfitting. Bland-Altman was used for the final evaluation of sensor pair performance. Several sensor pairs yielded limits of agreement comparable to the rated accuracy of a commercial infrared spectrometer. The ultrasonic and orifice-plate flowmeters yielded the most combinations of viable sensor pairs for all three volatile anesthetic gases. Conclusion: Measuring volatile anesthetic gases using flow sensor fusion is a feasible low-cost, low-maintenance alternative to infrared spectroscopy. In this study, testing was done under steady-state conditions in 100% oxygen. Further testing is necessary to ensure sensor fusion performance under conditions that are more reflective of the clinical use case.© 2021. The Author(s), under exclusive licence to Springer Nature B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.