• Cardiovasc Revasc Med · May 2020

    Comparative Study Observational Study

    Transfemoral Transcatheter Aortic Valve Replacement Using Fascia Iliaca Block as an Alternative Approach to Conscious Sedation as Compared to General Anesthesia.

    • Wei C Lau, Francis L Shannon, George S Hanzel, Robert D Safian, Amr E Abbas, Marc P Sakwa, Nai-Wei Chen, Steven L Almany, Ivan D Hanson, and Randy J Fayne.
    • Department of Anesthesiology, Beaumont Health System, Royal Oak, MI, United States of America. Electronic address: Wei.lau@beaumont.edu.
    • Cardiovasc Revasc Med. 2020 May 1; 21 (5): 594-601.

    Background/PurposeGeneral Anesthesia (GA) and conscious sedation (CS) are anesthetics for transfemoral transcatheter aortic valve replacement (TF-TAVR). We compared TF-TAVR outcomes using a novel anesthetic approach with fascia iliaca block (FIB) plus minimal CS (MCS) versus GA.MethodsThis retrospective propensity-matched study included consecutive TF-TAVR patients from January 2013 to December 2017 and dichotomized into FIB-MCS vs. GA. Data were collected from electronic records, Society of Thoracic Surgery (STS) database, and the Transcatheter Valve Therapies (TVT) Registry. Primary endpoints were operating room (OR) time, intensive care unit (ICU) and hospital length of stay (LOS). Secondary endpoints were 30-day, 1-year mortality, quality of life, 30-day re-hospitalization rate, failure of FIB-MCS, and hospital safety outcomes.ResultsA total of 304 TF-TAVR patients; FIB-MCS (n = 219) vs. GA (n = 85). Propensity matched 162 patients; FIB-MCS (n = 108) vs. GA (n = 54). FIB-MCS had shorter OR time (197.6 ± 56.3 vs. 248.2 ± 46.3 min, p < 0.001), ICU (67.8 ± 71.7 vs. 84.9 ± 72.1 h, p = 0.004) and hospital LOS (3.2 ± 3.7 vs. 5.9 ± 3.5 d, p < 0.001). FIB-MCS had lower rate of blood transfusion. FIB-MCA vs. GA 30-day and 1-year mortality were similar in the entire (2.3 vs. 2.4%, p = 1.0; and 8.2 vs. 5.9%, p = 0.49) and matched cohorts (0 vs. 3.7%, p = 0.11 and 7.4 vs. 5.6%, p = 0.75). FIB-MCS were less likely to be re-hospitalized [Odd Ratio: 0.32, CI:0.13-0.76] and 2% to 3% higher KCCQ-12 score.ConclusionTF-TAVR using FIB-MCS is feasible and safe with shorter OR time, ICU and hospital LOS, lower risk of 30-day re-hospitalization, similar 30-day and 1-year mortality with better quality of life at 1-year follow-up.Copyright © 2019 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…