-
Randomized Controlled Trial
Effect of a real-time feedback smartphone application (TCPRLink) on the quality of telephone-assisted CPR performed by trained laypeople in China: a manikin-based randomised controlled study.
- Xuejie Dong, Lin Zhang, Helge Myklebust, Tonje Soraas Birkenes, and Zhi-Jie Zheng.
- School of Public Health, Shanghai Jiao Tong University, Shanghai, China.
- BMJ Open. 2020 Oct 5; 10 (10): e038813.
ObjectivesTo determine the effect of a free smartphone application (TCPRLink) that provides real-time monitoring and audiovisual feedback on chest compressions (CC) on trained layperson telephone-assisted cardiopulmonary resuscitation (T-CPR) performance.DesignA manikin-based randomised controlled study.SettingThis study was conducted at a multidisciplinary university and a community centre in China.ParticipantsOne hundred and eighty-six adult participants (age 18-65 years) with T-CPR training experience were randomly assigned to the TCPRLink (n=94) and T-CPR (n=92) groups with age stratification.InterventionsWe compared the participants' performance for 6 min of CC in a simulated T-CPR scenario both at the baseline and after 3 months.Primary And Secondary Outcome MeasuresThe primary outcomes were the CC rate and proportion of adequate CC rate (100-120 min-1). The secondary outcomes included the proportion of participants counting the CC rhythm, time to first CC, CC depth, hands-off time and CC full-release ratio.ResultsParticipants in the TCPRLink feedback group more consistently performed CC with higher rate, both initially and 3 months later (median 111 (IQR 109-113) vs 108 (103-112) min-1, p=0.002 and 111 (109-113) vs 108 (105-112) min-1, p<0.001, respectively), with less need to count the rhythm (21.3% vs 41.3%, p=0.003% and 7% vs 22.6%, p=0.004, respectively) compared with the T-CPR group. There were no significant differences in time to the first CC, hands-off time or CC full-release ratio. Among 55-65 year group, the CC depth was deeper in the TCPRLink group than in the TCPR group (47.1±9.6 vs 38.5±8.7 mm, p=0.001 and 44.7±10.1 vs 39.3±10.8 mm, p=0.07, respectively).ConclusionsThe TCPRLink application improved T-CPR quality in trained laypersons to provide more effective CCs and lighten the load of counting out the CC with the dispatcher in a simulated T-CPR scenario. Further investigations are required to confirm this effectiveness in real-life resuscitation attempts.© Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.