• Heart Rhythm · Dec 2018

    Multicenter Study

    What is the real recurrence rate after cryoballoon-based pulmonary vein isolation? Lessons from rhythm follow-up based on implanted cardiac devices with continuous atrial monitoring.

    • Christian-Hendrik Heeger, Verena Tscholl, Omar Salloum, Erik Wissner, Thomas Fink, Laura Rottner, Peter Wohlmuth, Barbara Bellmann, Mattias Roser, Shibu Mathew, Bruno Reißmann, Christine Lemeš, Tilman Maurer, Francesco Santoro, Britta Goldmann, Ulf Landmesser, Feifan Ouyang, Karl-Heinz Kuck, Andreas Rillig, and Andreas Metzner.
    • Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany; University Heart Center Luebeck, Luebeck, Germany. Electronic address: christian.heeger@gmx.net.
    • Heart Rhythm. 2018 Dec 1; 15 (12): 1844-1850.

    BackgroundSecond-generation cryoballoon (CB2)-based pulmonary vein isolation (PVI) has demonstrated encouraging clinical results for the treatment of paroxysmal atrial fibrillation (AF) and persistent AF. However, rhythm follow-up after PVI is mainly based on Holter electrocardiography of limited duration.ObjectiveThe purpose of this study was to assess the real AF burden following CB2-based PVI in patients with implanted cardiac devices.MethodsA total of 670 consecutive patients underwent CB2-based PVI at 3 electrophysiology centers. In 66 patients (9.9%), an implantable cardiac device with continuous monitor function was independently implanted before the procedure (device group). This patient cohort was compared to propensity score-matched patients without cardiac devices (n = 66; control group).ResultsA total of 254 of 258 PVs (98.4%0 in the device group were successfully isolated using only CB2. Postprocedural device interrogation found no device or lead malfunction related to the procedure. Periprocedural complications were registered in 7 of 66 patients (11%) in the device group and in 6 of 66 patients (9%) in the control group (P = .770). Phrenic nerve palsy occurred in 6 of 66 patients (9%) in the device group) and in 2 of 66 patients (3%) in the control group) (P = .274). Clinical success in terms of freedom from AF recurrence after a 1-year follow-up period was 63.8% (95% confidence interval 53-77) in the device group and 77.3% (95% confidence interval 68-88) in the control group (P = .038). In the device group, AF/AT burden decreased from 41.8% ± 35.0% before the procedure to 10.2% ± 22.4% after 1 year (P <.0001).ConclusionCB2-PVI seems safe and feasible in patients with an implanted cardiac device. A significantly higher AF/AT burden was seen in patients with an implanted cardiac device compared to a control group.Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.