• Diabetes Technol. Ther. · May 2009

    Effect of steel and teflon infusion catheters on subcutaneous adipose tissue blood flow and infusion counter pressure in humans.

    • Lise Højbjerre, Camilla Skov-Jensen, Peter Kaastrup, Per Elgård Pedersen, and Bente Stallknecht.
    • Department of Biomedical Sciences, The Panum Institute, University of Copenhagen, Copenhagen, Denmark. hojbjerre@mfi.ku.dk
    • Diabetes Technol. Ther. 2009 May 1; 11 (5): 301-6.

    BackgroundSubcutaneous tissue is an important target for drug deposition or infusion. A local trauma may induce alterations in local microcirculation and diffusion barriers with consequences for drug bioavailability. We examined the influence of infusion catheters' wear time on local microcirculation and infusion counter pressure.MethodsOne steel catheter and one Teflon (Dupont, Wilmington, DE) catheter were inserted in subcutaneous, abdominal adipose tissue (SCAAT) in 10 healthy, lean men. The catheters were infused with isotonic saline at a rate of 10 microL/h for 48 h. Another steel catheter and a Teflon catheter were inserted contralateral to the previous catheters after 48 h. The infusion counter pressure was measured during a basal infusion rate followed by a bolus infusion. The measurements during a basal rate infusion were repeated after the bolus infusion. Adipose tissue blood flow (ATBF) was measured in SCAAT continuously.ResultsA significant increase in ATBF was observed with wear time for Teflon but not for steel catheters. Mean infusion pressure during the bolus phase increased significantly from 0 to 48 h for Teflon but not for steel catheters. ATBF and infusion counter pressure was similar between Teflon and steel catheters after acute catheter implantation and after wear time of 48 h. The maximum value of pressure during the bolus phase increased with wear time of a catheter.ConclusionsATBF and bolus mean infusion pressure increased significantly with a wear time of 48 h in Teflon but not in steel catheters. The maximal pressure required to deliver a bolus infusion increased with wear time of a catheter. A higher maximal pressure was required to deliver a bolus infusion through a Teflon than through a steel catheter. We propose that the difference in infusion counter pressure and ATBF between Teflon and steel catheters with wear time may be explained by better biocompatibility of steel than Teflon.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.