-
Zhonghua Yu Fang Yi Xue Za Zhi · Jan 2019
[Short-term effects of household indoor- and outdoor-originating fine particulate matters on heart rate and heart rate variability in chronic obstructive pulmonary diseases patients, Beijing].
- R Chi, L Pan, H Y Li, W Dong, D Y Hu, X Yang, Y H Chen, F R Deng, and X B Guo.
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing 100191, China.
- Zhonghua Yu Fang Yi Xue Za Zhi. 2019 Jan 6; 53 (1): 57-63.
AbstractObjective: To assess the associations of indoor fine particulate matter (PM(2.5)) from outdoor and indoor sources with heart rate (HR) and heart rate variability (HRV) in patients with chronic obstructive pulmonary disease (COPD) of Beijing. Methods: A total of 40 male patients in a stable stage of COPD were recruited from a hospital in a panel study in Beijing with 5 consecutive days of measurement for each subject. General information and disease history of the participants from questionnaires were obtained prior to the study. HR and HRV were repeatedly examined using dynamic electrocardiograph. HRV included standard deviation of all NN intervals (SDNN), root mean square of successive differences between adjacent NN intervals (rMSSD), total power (TP) power in the low-frequency band (LF) and the high-frequency band (HF). Iron was used as tracer element to separate indoor-originated PM(2.5) and outdoor-originated PM(2.5). Mixed-effect models were applied to assess the associations of outdoor-originated PM(2.5) or indoor-originated PM(2.5) and health effects. Results: The P(50) (P(25), P(75)) values of daily indoor PM(2.5), indoor-originated PM(2.5) and outdoor-originated PM(2.5) were 50.9 (26.8, 122.7), 16.0 (1.9, 43.7) and 27.3 (13.5, 61.8) μg/m(3), respectively. The mean±SD of concentrations of real-time indoor PM(2.5), indoor-originated PM(2.5) and outdoor-originated PM(2).5 were (61.5±58.8), (25.3±39.1) and (36.2±42.7) μg/m(3), respectively. Compared with outdoor-originated PM(2.5), indoor-originated PM(2.5) had significant associations with HRV and HR. Each 10 μg/m(3) increase at 4 h indoor-originated PM(2.5) and outdoor-originated PM(2.5) moving average was associated with 3.4% (95%CI: -4.7%, -2.1%) and 0.6% (95%CI: -2.0%, -0.8%) reduction in TP (P<0.001). Each 10 μg/m(3) increase at 12 h indoor-originated PM(2.5) moving average was associated with 7.6% (95%CI: -10.1%, -5.1%), 4.7% (95%CI: -6.7%, -2.7%), 3.3% (95%CI: -4.2%,-2.4%) and 3.0% (95%CI: -4.5%, -1.5%) reduction in HF, LF, SDNN and rMSSD, respectively. Each 10 μg/m(3) increase at 12 h outdoor-originated PM(2.5) moving average was associated with 0.7% (95%CI: -2.7%, -1.4%), 0.2% (95%CI: -1.9%, 1.4%), 0.7% (95%CI: -1.4%, -0.1%) and 0.2% (95%CI: -1.3%, 0.9%) reduction in HF, LF, SDNN and rMSSD, respectively (P<0.001). Each 10 μg/m(3) increase at 8 h indoor-originated PM(2.5) and outdoor-originated PM(2.5) moving average was associated with 0.7% (95%CI: 0.4%, 1.0%) and 0.4% (95%CI: 0.2%, 0.6%) increase in HR. Conclusion: Exposure to indoor-originated PM(2.5) was more strongly associations with HRV indices and HR compared with outdoor-originated PM(2.5) in male COPD patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.