    • IEEE Trans Biomed Eng. 2006 Feb 1; 53 (2): 347-51.

    AbstractWe presented a novel way of deriving a subspace filter for enhancing a noisy electrocardiogram (ECG) signal contaminated by electromyogram (EMG). The new subspace filter was based on a multiple cycle prediction (MCP) modeling of a single-lead ECG. The adoption of an MCP model resulted in a data matrix more suitable for separating noise and signal subspaces than the linear prediction (LP) model that is implicitly assumed in many existing subspace filters. Alignment of ECG cycles of different length is required for MCP modeling and was handled by a dynamic time warping (DTW) algorithm. A run-time procedure was designed for automatically determining the signal space dimension adaptively. To validate the new filter in a quantitative way, 12 clean realistic ECG segments with different degrees of heart rate variability generated using the ECGSyn program were mixed with different realizations of EMG noise in the MIT-BIH Noise Stress Test Database and locally acquired EMG at a typical 10-dB signal-to-noise ratio. The performance of the proposed method was compared to three existing ECG enhancement algorithms and achieved encouraging results. In addition, various ECG recordings from MIT-Arrythmia database were also mixed with EMG noise and subjected to the same four filters resulting in a qualitative comparison of them.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…