Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes.
The use of potential biasing and biphasic, asymmetric current pulse waveforms to maximize the charge-injection capacity of activated iridium oxide (AIROF) microelectrodes used for neural stimulation is described. The waveforms retain overall zero net charge for the biphasic pulse, but employ an asymmetry in the current and pulse widths of each phase, with the second phase delivered at a lower current density for a longer period of time than the leading phase. ⋯ For anodal-first pulsing, a maximum charge capacity of 9.6 mC/cm2 was obtained with an asymmetry of 1:3 at an 0.1-V bias. These measurements were made in vitro in carbonate-buffered saline using microelectrodes with a 2000 microm2 surface area.
-
IEEE Trans Biomed Eng · Feb 2006
Comparative StudyA single-lead ECG enhancement algorithm using a regularized data-driven filter.
We presented a novel way of deriving a subspace filter for enhancing a noisy electrocardiogram (ECG) signal contaminated by electromyogram (EMG). The new subspace filter was based on a multiple cycle prediction (MCP) modeling of a single-lead ECG. The adoption of an MCP model resulted in a data matrix more suitable for separating noise and signal subspaces than the linear prediction (LP) model that is implicitly assumed in many existing subspace filters. ⋯ To validate the new filter in a quantitative way, 12 clean realistic ECG segments with different degrees of heart rate variability generated using the ECGSyn program were mixed with different realizations of EMG noise in the MIT-BIH Noise Stress Test Database and locally acquired EMG at a typical 10-dB signal-to-noise ratio. The performance of the proposed method was compared to three existing ECG enhancement algorithms and achieved encouraging results. In addition, various ECG recordings from MIT-Arrythmia database were also mixed with EMG noise and subjected to the same four filters resulting in a qualitative comparison of them.
-
IEEE Trans Biomed Eng · Feb 2006
Microfabricated cylindrical multielectrodes for neural stimulation.
The effects of spinal cord injuries are likely to be ameliorated with the help of functional electrical stimulation of the spinal cord, a technique that may benefit from a new style of electrode: the cylindrical multielectrode. This paper describes the specifications for, fabrication techniques for, and in vitro evaluation of cylindrical multielectrodes. ⋯ The charge delivery capacity was determined by testing with safe (< or = 0.6 mC/cm2) and damaging levels (> or = 0.8 mC/cm2) of charge density. The results of these tests suggest that this electrode design could be used to stimulate neurons in the ventral horn of the spinal cord.