    AbstractOne hundred thirty-four patients with prosthetic or bioprosthetic heart valves were investigated with Doppler echocardiography to determine normal values for commonly used prosthetic valves and to test the specificity of abnormal Doppler findings. In 70 patients the aortic valves had been replaced and in 64 the mitral valves had been replaced. Gradients across prostheses in the aortic position were calculated from maximal velocity. Peak calculated aortic transvalvular gradients in normal subjects were 22 +/- 10 mm Hg in 33 Björk-Shiley valves, 23 +/- 10 mm Hg in 27 porcine valves and 29 +/- 13 mm Hg in 6 Starr-Edwards valves. Mild aortic regurgitation was seen in 42% of Björk-Shiley valves, 26% of porcine valves and 2 of 6 Starr-Edwards valves. Mitral valve orifice was calculated by the pressure half-time method. In clinically normal patients with mitral valve prostheses, the effective mitral valve orifice was 2.5 +/- 0.8 cm2 in 35 Björk-Shiley valves, 2.1 +/- 0.7 cm2 in 17 porcine valves, and 2.0 +/- 0.3 cm2 in 10 Starr-Edwards valves. Mitral regurgitation was found in 11% of Björk-Shiley valves, 19% of porcine valves and 30% of Starr-Edwards valves. Repeat studies at 2 weeks to 14 months revealed no difference in 8 aortic and 14 mitral prostheses. Seven aortic and 4 mitral valves functioned abnormally as determined by Doppler, and the abnormal function was confirmed in each at surgery or at cardiac catheterization.(ABSTRACT TRUNCATED AT 250 WORDS)

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…