-
Pacing Clin Electrophysiol · Dec 2003
Implantable cardioverter defibrillator events in patients with asymptomatic nonsustained ventricular tachycardia: is device implantation justified?
- Andrea M Russo, Hemal Nayak, Ralph Verdino, Jamie Springman, Edward Gerstenfeld, Henry Hsia, and Francis E Marchlinski.
- University of Pennsylvania Health System, Philadelphia, Pennsylvania 19104, USA. andrea_russo@uphs.upenn.edu
- Pacing Clin Electrophysiol. 2003 Dec 1; 26 (12): 2289-95.
AbstractPrimary prevention trials have demonstrated that patients with coronary disease, reduced left ventricular function, and nonsustained ventricular tachycardia (NSVT) have improved survival with implantable cardioverter defibrillator (ICD) therapy, presumably secondary to effective termination of life-threatening arrhythmias. However, stored intracardiac electrograms were not always available and specific arrhythmias leading to ICD therapy were not always known. We examined the occurrence of ICD events in 51 consecutive patients who match the described patient profile to determine the frequency of appropriate and inappropriate ICD therapy. ICD detections were noted in 18 (35%) patients during a median follow-up period of 13.1 months. Appropriate therapy for sustained ventricular tachycardia (VT)/ventricular fibrillation (VF) occurred in 11 (22%) patients, with appropriate shocks in 8 (16%) patients and appropriate antitachycardia pacing (ATP) in 4 (8%) patients. The time to first appropriate therapy occurred at a mean of 17 +/- 12 months (median 18 months, range 3-36 months). Inappropriate therapy occurred in 5 (10%) patients with inappropriate shocks in 4 patients and inappropriate ATP in 2 patients. Inappropriate therapy was delivered for supraventricular arrhythmias (SVAs) in 4 patients and for T wave oversensing in 1 patient. The reason for shock therapy was unknown in 1 patient (2%) due to ICD malfunction. The mean arrhythmia rate leading to appropriate therapy for VT/VF was 232 +/- 72 beats/min (range 181-400 beats/min), and the mean rate leading to inappropriate therapy for SVT was 168 +/- 10 beats/min (range 160-180 beats/min). Patients with coronary disease and asymptomatic NSVT commonly receive appropriate defibrillator therapy. These results support the need for ICD implantation for primary prevention, with attention to careful programming of the detection rate to prevent inappropriate therapy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.