• Minerva cardioangiologica · Apr 2018

    Multicenter Study Comparative Study

    Stentless sutureless and transcatheter valves: a comparison of the hemodynamic performance of different prostheses concept.

    • Alberto Repossini, Theodor Fischlein, Marco Solinas, Lorenzo DI Bacco, Bruno Passaretti, Herko Grubitzsch, Thierry Folliguet, Giuseppe Santarpino, Roberto DI Bartolomeo, François Laborde, and Claudio Muneretto.
    • University of Brescia, Clinical Department of Cardiovascular Surgery, Spedali Civili, Brescia, Italy - arepossini@yahoo.it.
    • Minerva Cardioangiol. 2018 Apr 1; 66 (2): 180-190.

    BackgroundStentless aortic valves have been developed to overcome obstructive limitations associated with stented bioprostheses. A new concept of surgical sutureless (SU) bioprosthesis has been developed in the last decade. In this multi-institutional study we sought to compare hemodynamics of different bioprosthesis concept as transcatheter (TAVR), Livanova Perceval S sutureless valve and Freedom Solo Stentless (FS) valve in patients undergoing aortic valve replacement (sAVR).MethodsFrom 2010 to 2016, 478 patients underwent sAVR with FS, 518 Perceval S and 367 patients underwent TAVR. After a propensity matched analysis 185 patients in each group were selected. Thirty-day postoperative clinical and echocardiographic parameters were evaluated. Echocardiographic hemodynamic data were also collected at 12 and 24 months.ResultsMean prosthesis diameter was 23.8±1.3 mm for FS, 23.2±2.1 mm for Perceval S and 25.1±2.6 mm for TAVR. In-hospital mortality was 2.0% for FS, 1.9% for Perceval, 5.8% for TAVR (P=0.02). Postoperative FS peak gradients were 15.6±9.1 mmHg (mean 7.6±5.4 mmHg); SU gradients were 18.7±9.1 mmHg (mean 10.9±5.4 mmHg), TAVR peak gradients were 14.7±9.1 mmHg (mean 6.1±5.4 mmHg) P=0.018 (P<0.001). Postoperative effective orifice area (EOA) was 1.94±0.7 cm² for FS, 1.6±0.7 cm² for SU and 1.97±0.7cm² for TAVR (P<0.001). There was no prostheses-patient-mismatch (PPM) in FS group, while 4 cases and 2 cases are reported in SU and TAVR respectively. Postoperative grade 2-3 paravalvular leak (PVL) was present in 4.3% for TAVR and 0.5% in SU valves and no cases in FS. Postoperative permanent pacemaker implant rate was 11.9% for TAVR (1.0%) in FS group and 5.4% in SU valves (P<0.001).ConclusionsSU patients demonstrated post-operative excellent hemodynamic performance with smaller EROA and higher gradients compared to FS and TAVR. TAVR demonstrated higher mortality and pacemaker rates. Further studies are warrented to validate TAVR indications in this subset of patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…