Physiological measurement · Jun 2005
Inertance measurements by jet pulses in ventilated small lungs after perfluorochemical liquid (PFC) applications.
- Gerd Schmalisch, Hans Proquitté, Mario Schmidt, Mario Rüdiger, and Roland R Wauer.
- Clinic of Neonatology (Charité), Humboldt-University of Berlin, Schumannstrasse 20/21, D-10098 Berlin, Germany. gerd.schmalisch@charite.de
- Physiol Meas. 2005 Jun 1; 26 (3): 239-49.
AbstractPerfluorochemical liquid (PFC) liquids or aerosols are used for assisted ventilation, drug delivery, lung cancer hyperthermia and pulmonary imaging. The aim of this study was to investigate the effect of PFC liquid on the inertance (I) of the respiratory system in newborn piglets using partial liquid ventilation (PLV) with different volumes of liquid. End-inspiratory (I(in)) and end-expiratory (I(ex)) inertance were measured in 15 ventilated newborn piglets (age < 12 h, mean weight 724 +/- 93 g) by brief flow pulses before and 80 min after PLV using a PFC volume (PF5080, 3 M) of 10 ml kg(-1) (N = 5) or 30 ml kg(-1) (N = 10). I was calculated from the imaginary part of the measured respiratory input impedance by regression analysis. Straight tubes with 2-4 mm inner diameter were used to validate the equipment in vitro by comparison with the analytically calculated values. In vitro measurements showed that the measuring error of I was <5% and that the reproducibility was better than 1.5%. The correlation coefficient of the regression model to determine I was >0.988 in all piglets. During gas ventilation, I(in) and I(ex) (mean +/- SD) were 31.7 +/- 0.8 Pa l(-1) s(2) and 33.3 +/- 2.1 Pa l(-1) s(2) in the 10 ml group and 32.4 +/- 0.8 Pa l(-1) s(2) and 34.0 +/- 2.5 Pa l(-1) s(2) in the 30 ml group. However, I of the 3 mm endotracheal tube (ETT) used was already 26.4 Pa l(-1) s(2) (about 80% of measured I). During PLV, there was a minimal increase of I(in) to 33.1 +/- 2.5 Pa l(-1) s(2) in the 10 ml group and to 34.5 +/- 2.7 Pa l(-1) s(2) in the 30 ml group. In contrast, the increase of I(ex) was dramatically larger (p < 0.001) to 67.7 +/- 13.3 Pa l(-1) s(2) and to 74.8 +/- 9.3 Pa l(-1) s(2) in the 10 ml and 30 ml groups, respectively. Measurements of I by jet pulses in intubated small animals are reproducible. PFC increases the respiratory inertance, but the magnitude depends considerably on its spatial distribution which changes during the breathing cycle. Large differences between I(in) and I(ex) are an indicator for liquid in airways or the ETT.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.