• Lasers Surg Med · Mar 2010

    Semiautomated intraocular laser surgery using handheld instruments.

    • Brian C Becker, Robert A MacLachlan, Louis A Lobes, and Cameron N Riviere.
    • The Robotics Institute, Carnegie Mellon University, 5000 Forbes Ave., Pittsburgh, Pennsylvania 15213, USA.
    • Lasers Surg Med. 2010 Mar 1; 42 (3): 264-73.

    Background And ObjectiveIn laser retinal photocoagulation, hundreds of dot-like burns are applied. We introduce a robot-assisted technique to enhance the accuracy and reduce the tedium of the procedure.Materials And MethodsLaser burn locations are overlaid on preoperative retinal images using common patterns such as grids. A stereo camera/monitor setup registers and displays the planned burn locations overlaid on real-time video. Using an active handheld micromanipulator, a 7 x 7 grid of burns spaced 650 microm apart is applied to both paper slides and porcine retina in vitro using 30 milliseconds laser pulses at 532 nm. Two scenarios were tested: unaided, in which the micromanipulator is inert and the laser fires at a fixed frequency, and aided, in which the micromanipulator actively targets burn locations and the laser fires automatically upon target acquisition. Error is defined as the distance from the center of the observed burn mark to the preoperatively selected target location.ResultsAn experienced retinal surgeon performed trials with and without robotic assistance, on both paper slides and porcine retina in vitro. In the paper slide experiments at an unaided laser repeat rate of 0.5 Hz, error was 125+/-62 microm with robotic assistance and 149+/-76 microm without (P < 0.005), and trial duration was 70+/-8 seconds with robotic assistance and 97+/-7 seconds without (P < 0.005). At a repeat rate of 1.0 Hz, error was 129+/-69 microm with robotic assistance and 166+/-91 microm without (P < 0.005), and trial duration was 26+/-4 seconds with robotic assistance and 47+/-1 seconds without (P < 0.005). At a repeat rate of 2.0 Hz on porcine retinal tissue, error was 123+/-69 microm with robotic assistance and 203+/-104 microm without (P < 0.005).ConclusionRobotic assistance can increase the accuracy of laser photocoagulation while reducing the duration of the operation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.