    Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography: in comparison with standard 120-kVp imaging protocol.

    • Chun-Ling Ma, Xiao-Xia Chen, Yu-Xin Lei, Xi-Rong Zhang, Yong-Jun Jia, Xin Tian, and Qian Tian.
    • Department of Radiology, Affiliated Hospital of Shaanxi University of Traditional Chinese Medicine, Xianyang, Shaanxi, People's Republic of China.
    • Br J Radiol. 2016 Jun 1; 89 (1062): 20151022.

    ObjectiveTo evaluate the clinical value of dual-energy spectral CT with adaptive statistical iterative reconstruction (ASiR) for reducing contrast medium dose in CT portal venography (CTPV).MethodsThis prospective study was institutional review board-approved, and written informed consent was obtained from all patients. 50 patients undergoing abdominal CT were randomized to 2 groups: Group A (n = 25), using spectral CT and 350 mgI kg(-1) contrast injection protocol; Group B (n = 25), using standard 120 kVp and 500 mgI kg(-1) contrast. Spectral CT images at 60 keV and standard 120-kVp images were both reconstructed with 50% ASiR. CT number and contrast-to-noise ratio (CNR) for intrahepatic and extrahepatic portal veins were measured. The maximum intensity projection (MIP) and volume-rendering (VR) images were used for subjective evaluation. These two kinds of results were statistically analyzed.ResultsCNR values for the intrahepatic portal vein of the 60-keV spectral images (4.2 ± 1.1) were higher than those of 120-kVp images (3.0 ± 2.1) (p = 0.03) and were the same for the extrahepatic portal vein (5.9 ± 1.4 vs 5.9 ± 1.6, p = 0.90). The portal vein and left and right branches in the 60-keV spectral images had higher CT number and lower standard deviation than the 120-kVp images (p < 0.05). Radiation dose (dose-length product and effective dose) and subjective image quality were similar for the two groups, while the spectral CT group required 25% less iodine dose (23.1 ± 3.2 g vs 30.5 ± 5.0 g).ConclusionThe 60-keV spectral CT images with ASiR allow 25% reduction in the iodine dose while providing better or equal image quality as the standard 120-kVp images in portal venography with comparable radiation dose.Advances In KnowledgeCompared with conventional 120-kVp CT, the use of 60-keV spectral CT images provides 25% contrast dose reduction with similar image quality in CTPV. Compared with conventional 120-kVp CT, the use of 60-keV spectral CT images with ASiR algorithm improves CNR values for the intrahepatic portal vein.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…