• Acta radiologica · Jun 2008

    Comparative Study

    Prostate cancer detection: comparison of T2-weighted imaging, diffusion-weighted imaging, proton magnetic resonance spectroscopic imaging, and the three techniques combined.

    • M Chen, H-D Dang, J-Y Wang, C Zhou, S-Y Li, W-C Wang, W-F Zhao, Z-H Yang, C-Y Zhong, and G-Z Li.
    • Department of Radiology, Beijing Hospital, Beijing, China. chenmin62@yahoo. com
    • Acta Radiol. 2008 Jun 1; 49 (5): 602-10.

    BackgroundMagnetic resonance (MR) imaging has been established as the best imaging modality for the detection, localization, and staging of prostate cancer on account of its high resolution of soft tissue and the possibilities of multiplanar and multiparameter scanning.PurposeTo evaluate T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), MR spectroscopy (MRS), and the combination of these three MR techniques in the diagnosis of prostate cancer, as correlated to histopathologic findings.Material And MethodsMR imaging, including T2WI, DWI, and MRS, was performed at 1.5T with a body coil combined with a spine coil in 42 cases. Diagnosis was confirmed by histopathology through systematic transrectal prostate biopsy. Apparent diffusion coefficient (ADC) maps were obtained with two b values (0 and 1000 s/mm(2)). The metabolic maps of 3D-MRS imaging were analyzed for the ratio of (Cho+Cre)/Cit in each sextant. All cases were evaluated by T2WI, DWI, and MRS, and then by the three methods combined. The statistical indicators and the receiver operating characteristic (ROC) curve analysis of each method were compared to the results of histopathology obtained by transrectal prostate biopsy.Results15 of 42 cases were confirmed to be cancerous, and 27 of 42 cases were noncancerous. All the 252 sextants were confirmed by biopsies, including 201 benign sextants and 51 malignant sextants. The sensitivity and the specificity for the detection of prostate cancer were 88.2% and 67.2% for T2WI, as the cutoff was 3; 82.4% and 81.6% for DWI, as the cutoff was 4; 84.3% and 98.0% for MRS, as the cutoff was 5; and 96.1% and 96.5% for the combined T2WI+DWI+MRS, as the cutoff was 4. In the ROC analysis, the correlative areas under the ROC curves (Az) were 0.848+/-0.030, 0.860+/-0.033, and 0.961+/-0.016 for T2WI, DWI, and MRS, respectively, and 0.978+/-0.009 for the combination of T2WI+DWI+MRS.ConclusionThe accuracy of the detection of prostate cancer is increased through a combination of the three techniques. Moreover, MRS demonstrated higher accuracy compared with T2WI or DWI.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…