• J Trauma Acute Care Surg · Dec 2020

    Plasmin thrombelastography rapidly identifies trauma patients at risk for massive transfusion, mortality, and hyperfibrinolysis: A diagnostic tool to resolve an international debate on tranexamic acid?

    • Christopher D Barrett, Hunter B Moore, Navin Vigneshwar, Sanjeev Dhara, James Chandler, Michael P Chapman, Angela Sauaia, Ernest E Moore, and Michael B Yaffe.
    • From the Koch Institute for Integrative Cancer Research (C.D.B., S.D., M.B.Y.), Center for Precision Cancer Medicine, Massachusetts Institute of Technology, Cambridge; Division of Acute Care Surgery and Critical Care (C.D.B., M.B.Y.), Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts; Department of Surgery (H.B.M., N.V., A.S., E.E.M.), University of Colorado Denver, Denver, Colorado; Ernest E. Moore Shock and Trauma Center (J.C., E.E.M.), Denver Health Medical Center; and Department of Radiology (M.P.C.), University of Colorado Denver, Denver, Colorado.
    • J Trauma Acute Care Surg. 2020 Dec 1; 89 (6): 991-998.

    BackgroundTrauma patients with hyperfibrinolysis and depletion of fibrinolytic inhibitors (DFIs) measured by thrombelastography (TEG) gain clot strength with TXA, but TEG results take nearly an hour. We aimed to develop an assay, plasmin TEG (P-TEG), to more expeditiously stratify risk for massive transfusion (MT), mortality, and hyperfibrinolysis.MethodsTrauma patients (N = 148) were assessed using TEG assays without exogenous additives (rapid/native), with exogenous plasmin (P-TEG) or tissue plasminogen activator (tPA TEG). The plasmin dose used does not effect healthy-control clot lysis 30 minutes after maximum amplitude (LY30) but causes shortened reaction time (R time) relative to native TEG (P-TEG R time < native TEG R time considered P-TEG negative). If P-TEG R time is greater than or equal to native TEG R time, the patient was considered P-TEG positive. Each assay's ability to predict MT, mortality, and (risk for) hyperfibrinolysis was determined. χ and Mann-Whitney U tests were used to compare categorical and continuous variables, respectively. Results were reported as median ± interquartile range or n (%).ResultsPlasmin TEG provided results faster than all other assays (4.7 ± 2.5-9.1 minutes), approximately 11-fold faster than rapid-TEG (rTEG) LY30 (54.2 ± 51.1-58.1 minutes; p < 0.001). Plasmin TEG-positive patients had greater than fourfold higher MT rate (30% vs. 7%; p = 0.0015) with an area under the receiver operating characteristic curve of 0.686 (p = 0.028), greater than fourfold higher 24-hour mortality (33.3% vs. 7.8%; p = 0.0177), greater than twofold higher 30-day mortality (35% vs. 16.4%; p = 0.0483), higher rates of DFI (55% vs. 18%; p < 0.001), and a trend toward elevated D-dimer (19.9 vs. 3.3 μg/mL; p = 0.14). Plasmin TEG was associated with hyperfibrinolysis on rTEG LY30 at the 7.6% threshold (p = 0.04) but not the 3% threshold (p = 0.40). Plasmin TEG performed best in relation to DFI, with a positive predictive value of 58% and negative predictive value of 81%. When combined with tPA TEG time to maximum amplitude, P-TEG outperformed rTEG LY30 for predicting MT (area under the receiver operating characteristic curve, 0.811 vs. 0.708).ConclusionWithin 5 minutes, P-TEG can stratify patients at highest risk for MT, mortality, and risk for hyperfibrinolysis. In composite with tPA TEG time to maximum amplitude, P-TEG outperforms rTEG LY30 for predicting MT and does so four times faster (12.7 vs. 54.1 minutes). The rapid results of P-TEG may be useful for those who practice selective TXA administration to maximize TXA's time-dependent efficacy.Level Of EvidenceDiagnostic test, level V.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.