Analysis of an automated background correction method for cardiovascular MR phase contrast imaging in children and young adults.
- Cynthia K Rigsby, Nicholas Hilpipre, Gary R McNeal, Gang Zhang, Emma E Boylan, Andrada R Popescu, Grace Choi, Andreas Greiser, and Jie Deng.
- Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital of Chicago, 225 E. Chicago Ave, Box 9, Chicago, IL, 60611, USA, crigsby@luriechildrens.org.
- Pediatr Radiol. 2014 Mar 1; 44 (3): 265-73.
BackgroundPhase contrast magnetic resonance imaging (MRI) is a powerful tool for evaluating vessel blood flow. Inherent errors in acquisition, such as phase offset, eddy currents and gradient field effects, can cause significant inaccuracies in flow parameters. These errors can be rectified with the use of background correction software.ObjectiveTo evaluate the performance of an automated phase contrast MRI background phase correction method in children and young adults undergoing cardiac MR imaging.Materials And MethodsWe conducted a retrospective review of patients undergoing routine clinical cardiac MRI including phase contrast MRI for flow quantification in the aorta (Ao) and main pulmonary artery (MPA). When phase contrast MRI of the right and left pulmonary arteries was also performed, these data were included. We excluded patients with known shunts and metallic implants causing visible MRI artifact and those with more than mild to moderate aortic or pulmonary stenosis. Phase contrast MRI of the Ao, mid MPA, proximal right pulmonary artery (RPA) and left pulmonary artery (LPA) using 2-D gradient echo Fast Low Angle SHot (FLASH) imaging was acquired during normal respiration with retrospective cardiac gating. Standard phase image reconstruction and the automatic spatially dependent background-phase-corrected reconstruction were performed on each phase contrast MRI dataset. Non-background-corrected and background-phase-corrected net flow, forward flow, regurgitant volume, regurgitant fraction, and vessel cardiac output were recorded for each vessel. We compared standard non-background-corrected and background-phase-corrected mean flow values for the Ao and MPA. The ratio of pulmonary to systemic blood flow (Qp:Qs) was calculated for the standard non-background and background-phase-corrected data and these values were compared to each other and for proximity to 1. In a subset of patients who also underwent phase contrast MRI of the MPA, RPA, and LPA a comparison was made between standard non-background-corrected and background-phase-corrected mean combined flow in the branch pulmonary arteries and MPA flow. All comparisons were performed using the Wilcoxon sign rank test (α = 0.05).ResultsEighty-five children and young adults (mean age 14 years; range 10 days to 32 years) met the criteria for inclusion. Background-phase-corrected mean flow values for the Ao and MPA were significantly lower than those for non-background-corrected standard Ao (P = 0.0004) and MPA flow values (P < 0.0001), respectively. However, no significant difference was seen between the standard non-background (P = 0.295) or background-phase-corrected (P = 0.0653) mean Ao and MPA flow values. Neither the mean standard non-background-corrected (P = 0.408) nor the background-phase-corrected (P = 0.0684) Qp:Qs was significantly different from 1. However in the 27 patients with standard non-background-corrected data, the difference between the Ao and MPA flow values was greater than 10%. There were 19 patients with background-phase-corrected data in which the difference between the Ao and MPA flow values was greater than 10%. In the subset of 43 patients who underwent MPA and branch pulmonary artery phase contrast MRI, the sum of the standard non-background-corrected mean RPA and LPA flow values was significantly different from the standard non-background-corrected mean MPA flow (P = 0.0337). The sum of the background-phase-corrected mean RPA and LPA flow values was not significantly different from the background-phase-corrected mean MPA flow value (P = 0.1328), suggesting improvement in pulmonary artery flow calculations using background-phase-correction.ConclusionOur data suggest that background phase correction of phase contrast MRI data does not significantly change Qp:Qs quantification, and there are residual errors in expected Qp:Qs quantification despite background phase correction. However the use of background phase correction does improve quantification of MPA flow relative to combined RPA and LPA flow. Further work is needed to validate these findings in other patient populations, using other MRI units, and across vendors.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.