• Br J Radiol · Jan 2013

    Comparative Study

    Comparative assessment of three image reconstruction techniques for image quality and radiation dose in patients undergoing abdominopelvic multidetector CT examinations.

    • G S Desai, A Thabet, A Y A Elias, and D V Sahani.
    • Department of Radiology, Harvard Medical School, Boston, MA, USA.
    • Br J Radiol. 2013 Jan 1; 86 (1021): 20120161.

    ObjectiveTo compare image quality and radiation dose of abdominal CT examinations reconstructed with three image reconstruction techniques.MethodsIn this Institutional Review Board-approved study, contrast-enhanced (CE) abdominopelvic CT scans from 23 patients were reconstructed using filtered back projection (FBP), adaptive statistical iterative reconstruction (ASiR) and iterative reconstruction in image space (IRIS) and were reviewed by two blinded readers. Subjective (acceptability, sharpness, noise and artefacts) and objective (noise) measures of image quality were recorded for each image data set. Radiation doses in CT dose index (CTDI) dose-length product were also calculated for each examination type and compared. Imaging parameters were compared using the Wilcoxon signed rank test and a paired t-test.ResultsAll 69 CECT examinations were of diagnostic quality and similar for overall acceptability (mean grade for ASiR, 3.9±0.3; p=0.2 for Readers 1 and 2; IRIS, 3.9±0.4, p=0.2; FBP, 3.8±0.9). Objective noise was considerably lower with both iterative techniques (p<0.0001 and 0.0016 for ASiR and IRIS). Recorded mean radiation dose, i.e. CTDI(vol), was 24% and 10% less with ASiR (11.4±3.4 mGy; p<0.001) and IRIS (13.5±3.7 mGy; p=0.06), respectively, than with FBP: 15.0±3.5 mGy.ConclusionAt the system parameters used in this study, abdominal CT scans reconstructed with ASiR and IRIS provide diagnostic images with reduced image noise and 10-24% lower radiation dose than FBP.Advances In KnowledgeCT images reconstructed with FBP are frequently noisy on lowering the radiation dose. Newer iterative reconstruction techniques have different approaches to produce images with less noise; ASiR and IRIS provide diagnostic abdominal CT images with reduced image noise and radiation dose compared with FBP. This has been documented in this study.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…