• Bmc Neurol · Jun 2020

    Short-echo-time magnitude image derived from quantitative susceptibility mapping could resemble neuromelanin-sensitive MRI image in substantia nigra.

    • Xue Ling Liu, Li Qin Yang, Feng Tao Liu, Pu-Yeh Wu, Yong Zhang, Han Zhuang, Yong Hong Shi, Jian Wang, Dao Ying Geng, and Yu Xin Li.
    • Department of Radiology, Huashan Hospital, Fudan University, Shanghai, 200040, China.
    • Bmc Neurol. 2020 Jun 30; 20 (1): 262.

    BackgroundIn this study, we explored whether the proposed short-echo-time magnitude (setMag) image derived from quantitative susceptibility mapping (QSM) could resemble NM-MRI image in substantia nigra (SN), by quantitatively comparing the spatial similarity and diagnosis performances for Parkinson's disease (PD).MethodsQSM and NM-MRI were performed in 18 PD patients and 15 healthy controls (HCs). The setMag images were calculated using the short-echo-time magnitude images. Bilateral hyperintensity areas of SN (SNhyper) were manually segmented on setMag and NM-MRI images by two raters in a blinded manner. The inter-rater reliability was evaluated by the intraclass correlation coefficients (ICC) and the Dice similarity coefficient (DSC). Then the inter-modality (i.e. setMag and NM-MRI) spatial similarity was quantitatively assessed using DSC and volume of the consensual voxels identified by both of two raters. The performances of mean SNhyper volume for PD diagnosis on setMag and NM-MRI images were evaluated using receiver operating characteristic (ROC) analysis.ResultsThe SNhyper segmented by two raters showed substantial to excellent inter-rater reliability for both setMag and NM-MRI images. The DSCs of SNhyper between setMag and NM-MRI images showed substantial to excellent voxel-wise overlap in HCs (0.80 ~ 0.83) and PD (0.73 ~ 0.76), and no significant difference was found between the SNhyper volumes of setMag and NM-MRI images in either HCs or PD (p > 0.05). The mean SNhyper volume was significantly decreased in PD patients in comparison with HCs on both setMag images (77.61 mm3 vs 95.99 mm3, p < 0.0001) and NM-MRI images (79.06 mm3 vs 96.00 mm3, p < 0.0001). Areas under the curve (AUCs) of mean SNhyper volume for PD diagnosis were 0.904 on setMag and 0.906 on NM-MRI images. No significant difference was found between the two curves (p = 0.96).ConclusionsSNhyper on setMag derived from QSM demonstrated substantial spatial overlap with that on NM-MRI and provided comparable PD diagnostic performance, providing a new QSM-based multi-contrast imaging strategy for future PD studies.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…