-
Int. J. Radiat. Oncol. Biol. Phys. · Jun 2007
Automatic segmentation of pelvic structures from magnetic resonance images for prostate cancer radiotherapy.
- David Pasquier, Thomas Lacornerie, Maximilien Vermandel, Jean Rousseau, Eric Lartigau, and Nacim Betrouni.
- Département Universitaire de Radiothérapie, Centre Oscar Lambret, Université Lille II, Lille, France. d-pasquier@o-lambret.fr
- Int. J. Radiat. Oncol. Biol. Phys. 2007 Jun 1; 68 (2): 592-600.
PurposeTarget-volume and organ-at-risk delineation is a time-consuming task in radiotherapy planning. The development of automated segmentation tools remains problematic, because of pelvic organ shape variability. We evaluate a three-dimensional (3D), deformable-model approach and a seeded region-growing algorithm for automatic delineation of the prostate and organs-at-risk on magnetic resonance images.Methods And MaterialsManual and automatic delineation were compared in 24 patients using a sagittal T2-weighted (T2-w) turbo spin echo (TSE) sequence and an axial T1-weighted (T1-w) 3D fast-field echo (FFE) or TSE sequence. For automatic prostate delineation, an organ model-based method was used. Prostates without seminal vesicles were delineated as the clinical target volume (CTV). For automatic bladder and rectum delineation, a seeded region-growing method was used. Manual contouring was considered the reference method. The following parameters were measured: volume ratio (Vr) (automatic/manual), volume overlap (Vo) (ratio of the volume of intersection to the volume of union; optimal value = 1), and correctly delineated volume (Vc) (percent ratio of the volume of intersection to the manually defined volume; optimal value = 100).ResultsFor the CTV, the Vr, Vo, and Vc were 1.13 (+/-0.1 SD), 0.78 (+/-0.05 SD), and 94.75 (+/-3.3 SD), respectively. For the rectum, the Vr, Vo, and Vc were 0.97 (+/-0.1 SD), 0.78 (+/-0.06 SD), and 86.52 (+/-5 SD), respectively. For the bladder, the Vr, Vo, and Vc were 0.95 (+/-0.03 SD), 0.88 (+/-0.03 SD), and 91.29 (+/-3.1 SD), respectively.ConclusionsOur results show that the organ-model method is robust, and results in reproducible prostate segmentation with minor interactive corrections. For automatic bladder and rectum delineation, magnetic resonance imaging soft-tissue contrast enables the use of region-growing methods.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.