• Magn Reson Med · Nov 2019

    Robust pCASL perfusion imaging using a 3D Cartesian acquisition with spiral profile reordering (CASPR).

    • Joshua S Greer, Xinzeng Wang, Yiming Wang, Marco C Pinho, Joseph A Maldjian, Ivan Pedrosa, and Ananth J Madhuranthakam.
    • Department of Bioengineering, University of Texas at Dallas, Richardson, Texas.
    • Magn Reson Med. 2019 Nov 1; 82 (5): 1713-1724.

    PurposeTo improve the robustness of arterial spin-labeled measured perfusion using a novel Cartesian acquisition with spiral profile reordering (CASPR) 3D turbo spin echo (TSE) in the brain and kidneys.MethodsThe CASPR view ordering followed a pseudo-spiral trajectory on a Cartesian grid, by sampling the center of k-space at the beginning of each echo train of a segmented 3D TSE acquisition. With institutional review board approval and written informed consent, 14 normal subjects (9 brain and 5 kidneys) were scanned with pCASL perfusion imaging using 3D CASPR and compared against 3D linear TSE (brain and kidneys), the established 2D EPI and 3D gradient and spin echo perfusion (brain), and 2D single-shot turbo spin-echo perfusion (kidneys). The SNR and the quantitative perfusion values were compared among different acquisitions.Results3D CASPR TSE achieved robust perfusion across all slices compared to 3D linear TSE in the brain and kidneys. Compared to 2D EPI, 3D CASPR TSE showed higher SNR across the brain (P < 0.01), and exhibited good agreement (36.4 ± 4.7 and 36.9 ± 5.3 mL/100 g/min with 2D EPI and 3D CASPR, respectively), and with 3D gradient and spin echo (27.9 ± 7.2 mL/100 g/min). Compared to a single slice 2D single-shot turbo spin-echo acquisition, 3D CASPR TSE achieved robust perfusion across the entire kidneys in similar scan time with comparable quantified perfusion values (154.1 ± 74.6 and 151.7 ± 70.6 mL/100 g/min with 2D single-shot turbo spin-echo and 3D CASPR, respectively).ConclusionThe CASPR view ordering with 3D TSE achieves robust arterial spin-labeled perfusion in the brain and kidneys because of the sampling of the center of k-space at the beginning of each echo train.© 2019 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.