• J Clin Monit Comput · Oct 2016

    Does using two Doppler cardiac output monitors in tandem provide a reliable trend line of changes for validation studies?

    • Huang Li, Lester A H Critchley, and Jie Zhang.
    • Department of Anaesthesia and Surgical Intensive Care, Peking University First Hospital, Beijing, China.
    • J Clin Monit Comput. 2016 Oct 1; 30 (5): 559-67.

    AbstractThe demise of the pulmonary artery catheter as a gold standard in cardiac output measurement has created the need for new standard. Doppler cardiac output can be measured suprasternally (USCOM) and via the oesophagus (CardioQ). Use in tandem they may provide a reliable trend line of cardiac output changes against which new technologies can be assessed. Data from three similar clinical studies was pooled. Simultaneous USCOM and CardioQ readings, 13 (7-27), were performed every 15-30 min intraoperatively. Within individual patient regression analysis was performed. Data was normalized, CardioQ against USCOM, to eliminate the systematic error component following calibration. Bland-Altman and trend, concordance and polar analysis, were performed on the grouped data. Cardiac output was indexed (CI) to BSA. Data from 53 patients, aged 59 (26-81) years, scheduled for major surgery were included. Within-individual mean (SD) CI was 3.4 (0.6) L min(-1) m(-2). Correlation was good to excellent in 83 % of cases, R(2) > 0.80, and reasonable in 96 %, R(2) > 0.60. Percentage error was 38 %, and decreased to 14 % with normalization. The estimated 95 % precision for a single Doppler reading was ±10 %. Concordance rate was 96.6 % (confidence intervals 94.7-99.5 %) and above the >92 % threshold for good trending ability. Polar analysis also confirmed good trending ability. The regression line between Doppler methods was offset with a slope of 0.9, thus CardioQ CI readings increased relative to USCOM. Both Doppler methods trended cardiac output reliably. Used in tandem they provide a new standard to assess cardiac output trending.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.