• AJR Am J Roentgenol · Jan 2018

    American College of Radiology-Compliant Short Protocol Breast MRI for High-Risk Breast Cancer Screening: A Prospective Feasibility Study.

    • Basak E Dogan, Marion E Scoggins, Jong Bum Son, Wei Wei, Rosalind Candelaria, Wei T Yang, and Jingfei Ma.
    • 1 Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX.
    • AJR Am J Roentgenol. 2018 Jan 1; 210 (1): 214-221.

    ObjectiveThe purpose of this study was to assess the feasibility of a short protocol for screening breast MRI that is noninferior to standard-of-care (SOC) MRI in image quality that complies with American College of Radiology accreditation requirements.Subjects And MethodsIn a prospective feasibility trial, 23 women at high risk underwent both an initial SOC MRI examination that included axial iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) and T1-weighted volume imaging for breast assessment (VIBRANT) dynamic contrast-enhanced sequences and a separate short breast MRI protocol comprising a fast spin-echo (FSE) triple-echo Dixon T2 sequence for T2-weighted imaging and a 3D dual-echo fast spoiled gradient-echo two-point Dixon sequence for dynamic contrast-enhanced imaging from October 1, 2015, through May 2, 2016. Image quality assessment was performed by three radiologists, who scored the images for fat saturation, artifact severity, and quality of normal anatomic structures. Enhancing lesions were evaluated according to BI-RADS MRI features. Quantitative analysis was performed by measuring the signal intensity of anatomic areas in each patient.ResultsThe mean acquisition time for short-protocol breast MRI was 9.42 minutes and for SOC MRI was 22.09 minutes (p < 0.0001). The mean table times were 13.92 and 35.87 minutes (p < 0.0001). Compared with the FSE triple-echo Dixon T2 short-protocol breast MRI sequence, the IDEAL SOC MRI sequence had significantly worse motion artifact (p < 0.01) and fat saturation (p = 0.04). The other parameters did not differ significantly. Quantitative analysis showed that the FSE triple-echo Dixon T2 sequence had more effective fat saturation and higher tissue contrast. All five lesions were given the same assessments by the readers, and at BI-RADS lesion morphologic ranking, identical high image quality scores were assigned to both the VIBRANT and 3D dual-echo fast spoiled gradient-echo 2-point Dixon sequences.ConclusionShort-protocol breast MRI comprising a T2-weighted sequence and a fast dynamic sequence with less than 10-minute acquisition time is feasible and has image quality at least equivalent to that of an SOC MRI protocol with a > 20-minute mean acquisition time. Larger studies comparing the cancer detection rate, sensitivity, and specificity of each imaging protocol are needed to determine whether short-protocol breast MRI can replace SOC MRI to screen patients at high breast cancer risk.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…