• Acta paediatrica · Sep 2001

    Hepatic technetium-99m-mebrofenin iminodiacetate scans and serum gamma-glutamyl transpeptidase levels interpreted in series to differentiate between extrahepatic biliary atresia and neonatal hepatitis.

    • N K Arora, R Kohli, D K Gupta, C S Bal, A K Gupta, and S D Gupta.
    • Department of Pediatrics, All India Institute of Medical Sciences, New Delhi. nkmanan@hotmail.com
    • Acta Paediatr. 2001 Sep 1; 90 (9): 975-81.

    UnlabelledHepatic technetium-99m-mebrofenin iminodiacetate (99mTc-mebrofenin IDA) scans and serum gamma-glutamyl transpeptidase (GGTP) have high sensitivity for extrahepatic biliary atresia (EHBA). This study was based on the hypothesis that the interpretation of results of 99mTc-mebrofenin IDA scans and serum GGTP levels in series would result in a reduction of the false positivity observed with these tests individually. The aetiology of neonatal cholestasis in 132 study patients was: 25% (33/132) EHBA, 45.5% (60/132) neonatal hepatitis (NH) with an identifiable cause and 19.7% (26/132) idiopathic NH. Of the various clinical, biochemical and imaging parameters that were significantly different between patient groups, sensitivity for EHBA was: serum GGTP > or = 150 IU l(-1) (100%), 99mTc-mebrofenin IDA scans (100%), pale stools (82.8%) and total serum bilirubin > or = 12 mg dl(-1) (66%). However, specificity ranged from 48.5 to 79%. Of the 63 patients who had non-excreting IDA scans, operative cholangiograms could be avoided on the basis of a specific aetiological diagnosis of NH, made concurrently, in only 9 infants. The rest (54) underwent operative cholangiograms; 21 (39%) of these had patent biliary trees and therefore underwent the procedure unnecessarily. If serum GGTP (< 150 IU l(-1)) had been used as a screen after IDA scanning in these 54 patients, operative cholangiograms could have been avoided in another 12 patients and thereafter only 9/42 (21%) of the operative cholangiograms would have been considered unnecessary.ConclusionA diagnostic algorithm is proposed wherein serum GGTP level (at a cut-off level that maintains 100% sensitivity for EHBA) is used in series with non-excreting 99mTc-mebrofenin IDA scans (for patients with no specific aetiological label). This strategy reduces the false positivity of individual tests.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.