• BMC anesthesiology · Jun 2021

    Randomized Controlled Trial Comparative Study

    AutoFlow® versus volume-controlled ventilation for laparoscopic gynecological surgery using LMA® ProSeal™: a randomized controlled trial.

    • Toshiyuki Nakanishi, Seishi Sakamoto, Manabu Yoshimura, and Takashi Toriumi.
    • Department of Anesthesiology, Japan Community Healthcare Organization Tokuyama Central Hospital, Shunan, Japan. nakanishi.anest@gmail.com.
    • BMC Anesthesiol. 2021 Jun 28; 21 (1): 181.

    BackgroundDuring laparoscopic gynecological surgery, increased peak airway pressure (PAWP) can cause airway leak upon ventilation with the LMA® ProSeal™. We hypothesized that compared with the use of volume-controlled ventilation (VCV), the use of the AutoFlow® mode would decrease PAWP and airway leak during laparoscopic gynecological surgery with LMA ProSeal.MethodsThis single-center, randomized, controlled trial allocated 80 adult women undergoing elective laparoscopic gynecological surgery to one of two groups, namely, the AutoFlow group or the VCV group. Ventilation settings for both groups were 8 ml/kg of tidal volume and 5 cmH2O of positive end-expiratory pressure, and respiratory rate was adjusted to maintain end-tidal carbon dioxide at 35-40 mmHg. Airway leak, PAWP, and other ventilatory parameters and vital signs were recorded at four timepoints (1, 1 min after insertion of the gastric tube; 2, 2 min after intravenous administration of rocuronium 0.6-0.8 mg/kg; 3, 1 min after initiation of pneumoperitoneum; and 4, 1 min after changing to the Trendelenburg position). The primary outcome was PAWP during pneumoperitoneum and in the Trendelenburg position, whereas the secondary outcomes included PAWP at other timepoints and airway leak development. We used the Mann-Whitney U test for PAWP and Fisher's exact test for comparing airway leak among the groups.ResultsData from 40 patients in the AutoFlow group and 39 in the VCV group were used for analysis. PAWP at pneumoperitoneum pressure and in the Trendelenburg position was significantly lower in the AutoFlow group than in the VCV group [median (interquartile range), 16 (15-18) cmH2O vs. 18 (17-19) cmH2O; P < 0.001]. Similarly, patients in the AutoFlow group showed lower PAWP at the other three timepoints measured. Airway leak occurred in four patients in the AutoFlow group and in two patients in the VCV group; however, this incidence was not significantly different (P = 0.68).ConclusionsEven though AutoFlow ventilation decreased PAWP, it did not reduce the incidence of airway leak compared with VCV during laparoscopic gynecological surgery with the LMA ProSeal.Trial RegistrationUMIN Clinical Trials Registry, identifier UMIN000023173 .

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…