BMC anesthesiology
-
Comparative Study
Effects of different vasopressors on the contraction of the superior mesenteric artery and uterine artery in rats during late pregnancy.
Hypotension after neuraxial anaesthesia is one of the most common complications during caesarean section. Vasopressors are the most effective method to improve hypotension, but which of these drugs is best for caesarean section is not clear. We assessed the effects of vasopressors on the contractile response of uterine arteries and superior mesenteric arteries in pregnant rats to identify a drug that increases the blood pressure of the systemic circulation while minimally affecting the uterine and placental circulation. ⋯ In vitro experiments showed that norepinephrine contracts peripheral blood vessels more strongly and had the least effect on uterine artery contraction. These findings support the use of norepinephrine in mothers between the time of neuraxial anaesthesia and the delivery of the foetus.
-
Randomized Controlled Trial Comparative Study
Intraoperative protective ventilation in patients undergoing major neurosurgical interventions: a randomized clinical trial.
Post-operative pulmonary complications (PPC) can develop in up to 13% of patients undergoing neurosurgical procedures and may adversely affect clinical outcome. The use of intraoperative lung protective ventilation (LPV) strategies, usually including the use of a low Vt, low PEEP and low plateau pressure, seem to reduce the risk of PPC and are strongly recommended in almost all surgical procedures. Nonetheless, feasibility of LPV strategies in neurosurgical patients are still debated because the use of low Vt during LPV might result in hypercapnia with detrimental effects on cerebrovascular physiology. Aim of our study was to determine whether LPV strategies would be feasible compared with a control group in adult patients undergoing cranial or spinal surgery. ⋯ LPV strategies in patients undergoing major neurosurgical intervention are feasible. Larger clinical trials are needed to assess their role in postoperative clinical outcome improvements.
-
Observational Study
Analysis of urgent/emergent conversions from monitored anesthesia care to general anesthesia with airway instrumentation.
Monitored Anesthesia Care (MAC) is an anesthetic service involving the titration of sedatives/analgesics to achieve varying levels of sedation while avoiding general anesthesia (GA) and airway instrumentation. The goal of our study was to determine the overall incidence of conversion from MAC to general anesthesia with airway instrumentation and elucidate reasons and risk factors for conversion. ⋯ This is one of the first and largest retrospective studies aimed at identifying reasons and risk factors associated with the conversion of MAC to GA. These findings may be used to help better anticipate or prevent these events.
-
Randomized Controlled Trial
The impact of multimodal analgesia based enhanced recovery protocol on quality of recovery after laparoscopic gynecological surgery: a randomized controlled trial.
Our objective was to evaluate the impact of multimodal analgesia based enhanced recovery protocol on quality of recovery after laparoscopic gynecological surgery. ⋯ For minimally invasive laparoscopic gynecological surgery, multimodal analgesia based enhanced recovery protocol offered better pain relief, lower opioid use, earlier ambulation, faster bowel function recovery and higher patient satisfaction, while no improvement in QoR-40 score was found.
-
Randomized Controlled Trial Comparative Study
AutoFlow® versus volume-controlled ventilation for laparoscopic gynecological surgery using LMA® ProSeal™: a randomized controlled trial.
During laparoscopic gynecological surgery, increased peak airway pressure (PAWP) can cause airway leak upon ventilation with the LMA® ProSeal™. We hypothesized that compared with the use of volume-controlled ventilation (VCV), the use of the AutoFlow® mode would decrease PAWP and airway leak during laparoscopic gynecological surgery with LMA ProSeal. ⋯ Even though AutoFlow ventilation decreased PAWP, it did not reduce the incidence of airway leak compared with VCV during laparoscopic gynecological surgery with the LMA ProSeal.