-
- Sotirios Bisdas, Christian Braun, Marco Skardelly, Jens Schittenhelm, Tze Hern Teo, Choon Hua Thng, Uwe Klose, and Tong San Koh.
- Department of Neuroradiology, Eberhard Karls University, Tübingen, Germany.
- NMR Biomed. 2014 Oct 1; 27 (10): 1184-91.
AbstractThe purpose of this study was to correlate intravoxel incoherent motion (IVIM) imaging with classical perfusion-weighted MRI metrics in human gliomas. Parametric images for slow diffusion coefficient (D), fast diffusion coefficient (D*), and fractional perfusion-related volume (f) in patients with high-grade gliomas were generated. Maps of Fp (plasma flow), vp (vascular plasma volume), PS (permeability surface-area product), ve (extravascular, extracellular volume), E (extraction ratio), ke (influx ratio into the interstitium), and tc (vascular transit time) from dynamic contrast-enhanced (DCE) and dynamic susceptibility contrast-enhanced (DSC) MRI were also generated. A region-of-interest analysis on the contralateral healthy white matter and on the tumor areas was performed and the extracted parameter values were tested for any significant differences among tumor grades or any correlations. Only f could be significantly correlated to DSC-derived vp and tc in healthy brain tissue. Concerning the tumor regions, Fp was significantly positively correlated with D* and inversely correlated with f in DSC measurements. The D*, f, and f × D* values in the WHO grade III gliomas were non-significantly different from those in the grade IV gliomas. There was a trend to significant negative correlations between f and PS as well as between f × D* and ke in DCE experiments. Presumably due to different theoretical background, tracer properties and modeling of the tumor vasculature in the IVIM theory, there is no clearly evident link between D*, f and DSC- and DCE-derived metrics.Copyright © 2014 John Wiley & Sons, Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.