• Comput. Biol. Med. · Dec 2016

    T2-adjusted computed diffusion-weighted imaging: A novel method to enhance tumour visualisation.

    • Lin Cheng, Matthew D Blackledge, David J Collins, Matthew R Orton, Neil P Jerome, Thorsten Feiweier, Mihaela Rata, Veronica Morgan, Nina Tunariu, Martin O Leach, and Dow-Mu Koh.
    • Cancer Research UK Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, UK.
    • Comput. Biol. Med. 2016 Dec 1; 79: 92-98.

    PurposeTo introduce T2-adjusted computed DWI (T2-cDWI), a method that provides synthetic images at arbitrary b-values and echo times (TEs) that improve tissue contrast by removing or increasing T2 contrast in diffusion-weighted images.Materials And MethodsIn addition to the standard DWI acquisition protocol T2-weighted echo-planar images at multiple (≥2) echo times were acquired. This allows voxelwise estimation of apparent diffusion coefficient (ADC) and T2 values, permitting synthetic images to be generated at any chosen b-value and echo time. An analytical model is derived for the noise properties in T2-cDWI, and validated using a diffusion test-object. Furthermore, we present T2-cDWI in two example clinical case studies: (i) a patient with mesothelioma demonstrating multiple disease tissue compartments and (ii) a patient with primary ovarian cancer demonstrating solid and cystic disease compartments.ResultsMeasured image noise in T2-cDWI from phantom experiments conformed to the analytical model and demonstrated that T2-cDWI at high computed b-value/TE combinations achieves lower noise compared with conventional DWI. In patients, T2-cDWI with low b-value and long TE enhanced fluid signal while suppressing solid tumour components. Conversely, large b-values and short TEs overcome T2 shine-through effects and increase the contrast between tumour and fluid compared with conventional high-b-value DW images.ConclusionT2-cDWI is a promising clinical tool for improving image signal-to-noise, image contrast, and tumour detection through suppression of T2 shine-through effects.Copyright © 2016. Published by Elsevier Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…